Nicad Cell D4500mAh 1.2V Emergency Light Battery With Good Safety
Application:
Pos. | Application fields | Application of the product |
1 | Lighting | emergency lighting, emergency power supply, solar lights, searchlingts, flashlights |
2 | Power tools | electric drills, planers, saws, power granted |
3 | Electronic toys | remote control car, remote control boats, aircraft, model aircraft |
4 | Communication equipment | cordless phones, walkie-talkie |
5 | Other uses | electric shavers, massagers, electric tooth brush |
Product parameters:
Standard Charge Mode: 0.1C for 16 hours
Cycle Life: ≥500 times
Operating Temperature: (-20℃) - (+70℃)
Storage Temperature: (-30℃) - (+60℃)
Expected Life: 5 years
Packaging: Standard export package or customized package.
List Of Ni-CD High Temperature Cells:
Ni-Cd battery has high charge and discharge efficiency and good safety performance at high temperature and has long service life under condition of long term floating charge, which makes it very suitable for emergency lighting application.
Working temperature for Ni-Cd battery could be up to 55 degree, and even up to 70 degree, and expected service life could be up to 4 to 5 years.
Type | Model | Diemeter (mm) | Height (mm) | Capacity (mAh) | Voltage (V) | Operating Temperature (°C) |
AAA | GS-AAA30T | 10.5 +0 -0.7 | 43.0 ±0.5 | 300 | 1.2 | -20 to 70 |
GS-AAA30 | 10.5 +0 -0.7 | 43.0 ±0.5 | 300 | 1.2 | -20 to 55 | |
GS-AAA35 | 10.5 +0 -0.7 | 43.0 ±0.5 | 300 | 1.2 | -20 to 55 | |
AA | GS-AA800T | 14.5 +0 -0.7 | 50.0±0.5 | 800 | 1.2 | -20 to 70 |
GS-AA80 | 14.5 +0 -0.7 | 50.0±0.5 | 800 | 1.2 | -20 to 55 | |
GS-AA90T | 14.5 +0 -0.7 | 50.0±0.5 | 900 | 1.2 | -20 to 70 | |
GS-AA90 | 14.5 +0 -0.7 | 50.0±0.5 | 900 | 1.2 | -20 to 55 | |
GS-AA100 | 14.5 +0 -0.7 | 50.0±0.5 | 1000 | 1.2 | -20 to 55 | |
GS-AA110 | 14.5 +0 -0.7 | 50.0±0.5 | 1100 | 1.2 | -20 to 55 | |
A | GS-4/5A110T | 17.0 +0 -0.7 | 42.5±0.5 | 1100 | 1.2 | -20 to 70 |
GS-4/5A110 | 17.0 +0 -0.7 | 42.5±0.5 | 1100 | 1.2 | -20 to 55 | |
GS-4/5A120T | 17.0 +0 -0.7 | 42.5±0.5 | 1200 | 1.2 | -20 to 70 | |
GS-4/5A120 | 17.0 +0 -0.7 | 42.5±0.5 | 100 | 1.2 | -20 to 55 | |
GS-A130T | 17.0 +0 -0.7 | 49.5±0.5 | 1300 | 1.2 | -20 to 70 | |
GS-A130 | 17.0 +0 -0.7 | 49.5±0.5 | 1300 | 1.2 | -20 to 55 | |
GS-A140 | 17.0 +0 -0.7 | 49.5±0.5 | 1300 | 1.2 | -20 to 55 | |
SC | GS-4/5SC120T | 23.0 +0 -1.0 | 33.5±0.5 | 1200 | 1.2 | -20 to 70 |
GS-SC120T | 23.0 +0 -1.0 | 42.5±0.5 | 1200 | 1.2 | -20 to 70 | |
GS-SC120 | 23.0 +0 -1.0 | 42.5±0.5 | 1200 | 1.2 | -20 to 55 | |
GS-SC130T | 23.0 +0 -1.0 | 42.5±0.5 | 1300 | 1.2 | -20 to 70 | |
GS-SC130 | 23.0 +0 -1.0 | 42.5±0.5 | 1300 | 1.2 | -20 to 55 | |
GS-SC140T | 23.0 +0 -1.0 | 42.5±0.5 | 1400 | 1.2 | -20 to 70 | |
GS-SC140 | 23.0 +0 -1.0 | 42.5±0.5 | 1400 | 1.2 | -20 to 55 | |
GS-SC150T | 23.0 +0 -1.0 | 42.5±0.5 | 1500 | 1.2 | -20 to 70 | |
GS-SC150 | 23.0 +0 -1.0 | 42.5±0.5 | 1500 | 1.2 | -20 to 55 | |
GS-SC160T | 23.0 +0 -1.0 | 42.5±0.5 | 1600 | 1.2 | -20 to 70 | |
GS-SC160 | 23.0 +0 -1.0 | 42.5±0.5 | 1600 | 1.2 | -20 to 55 | |
GS-SC170T | 23.0 +0 -1.0 | 42.5±0.6 | 1700 | 1.2 | -20 to 70 | |
GS-SC170 | 23.0 +0 -1.0 | 42.5±0.6 | 1700 | 1.2 | -20 to 55 | |
GS-SC180T | 23.0 +0 -1.0 | 42.5±0.5 | 1800 | 1.2 | -20 to 70 | |
GS-SC180 | 23.0 +0 -1.0 | 42.5±0.5 | 1800 | 1.2 | -20 to 55 | |
GS-SC190T | 23.0 +0 -1.0 | 42.5±0.5 | 1900 | 1.2 | -20 to 70 | |
GS-SC190 | 23.0 +0 -1.0 | 42.5±0.5 | 1900 | 1.2 | -20 to 55 | |
GS-SC200T | 23.0 +0 -1.0 | 42.5±0.5 | 2000 | 1.2 | -20 to 70 | |
GS-SC200 | 23.0 +0 -1.0 | 42.5±0.5 | 2000 | 1.2 | -20 to 55 | |
GS-SC210 | 23.0 +0 -1.0 | 42.5±0.5 | 2100 | 1.2 | -20 to 55 | |
C | GS-C220T | 25.8 +0 -1.0 | 49.5±0.5 | 2200 | 1.2 | -20 to 70 |
GS-C220 | 25.8 +0 -1.0 | 49.5±0.5 | 2200 | 1.2 | -20 to 55 | |
GS-C250T | 25.8 +0 -1.0 | 49.5±0.5 | 2500 | 1.2 | -20 to 70 | |
GS-C250 | 25.8 +0 -1.0 | 49.5±0.5 | 2500 | 1.2 | -20 to 55 | |
GS-C280T | 25.8 +0 -1.0 | 49.5±0.5 | 2800 | 1.2 | -20 to 70 | |
GS-C280 | 25.8 +0 -1.0 | 49.5±0.5 | 2800 | 1.2 | -20 to 55 | |
GS-C300T | 25.8 +0 -1.0 | 49.5±0.5 | 3000 | 1.2 | -20 to 70 | |
GS-C300 | 25.8 +0 -1.0 | 49.5±0.5 | 3000 | 1.2 | -20 to 55 | |
D | GS-D400T | 33.0 +0 -1.0 | 60.0+0 -1.5 | 4000 | 1.2 | -20 to 70 |
GS-D400 | 33.0 +0 -1.0 | 60.0+0 -1.5 | 4000 | 1.2 | -20 to 55 | |
GS-D450T | 33.0 +0 -1.0 | 60.0+0 -1.5 | 4500 | 1.2 | -20 to 70 | |
GS-D450 | 33.0 +0 -1.0 | 60.0+0 -1.5 | 4500 | 1.2 | -20 to 55 | |
GS-D500T | 33.0 +0 -1.0 | 60.0+0 -1.5 | 5000 | 1.2 | -20 to 70 | |
GS-D500 | 33.0 +0 -1.0 | 60.0+0 -1.5 | 5000 | 1.2 | -20 to 55 | |
GS-1/2D220T | 33.0 +0 -1.0 | 36.0 +0 -1.5 | 2200 | 1.2 | -20 to 70 | |
GS-1/2D220 | 33.0 +0 -1.0 | 36.0 +0 -1.5 | 2200 | 1.2 | -20 to 55 | |
GS-1/2D250 | 33.0 +0 -1.0 | 36.0 +0 -1.5 | 2500 | 1.2 | -20 to 55 | |
F | GS-F700T | 33.0 +0 -1.0 | 90.0 +0 -1.5 | 7000 | 1.2 | -20 to 70 |
GS-F700 | 33.0 +0 -1.0 | 90.0 +0 -1.5 | 7000 | 1.2 | -20 to 55 |
Ni-Cd Battery Cell Performance:
1. Ni-Cd Cell Charge Curve At 0.1C For 16h At 55 Degree
2. Ni-Cd Cell Discharge Curve At 0.25C At 55 Degree
3. Ni-Cd Cell Charge Efficiency At Different Temperature
4. Ni-Cd Cell Capacity Change At Permanent Charge At 55 Degree (0.05C Floating)
5. Ni-Cd Cell Cycle Life Curve