Specifications
Brand Name :
YBX
Model Number :
YB11A12-20A-Q
Certification :
cUL, TUV, CQC, CE, ROHS
Place of Origin :
China
MOQ :
100pcs
Price :
Negotiable
Payment Terms :
T/T, L/C
Supply Ability :
10000 Piece/Pieces per Month
Delivery Time :
20-25 days
Packaging Details :
56.5*28.5*22.5cm
Item :
YB11A12-20A-Q
Rated current :
1A-20A
Rated voltage :
110V
Operating Frequency :
50/60HZ
Line to Line :
1450DVC
Port :
Shenzhen
Description

20A Inline EMI Filter EMC Power Line Filter For Medical Equipment 120V, 250V

Technical Specification:

Item IEC Filter
Model IEC Filter YB-A
Transfer Function Low Pass
Package Type Surface Mount
Nominal Center Frequency 10K-30MHZ
Insertion Loss 60~90dB
Input Impedance 50Ω
Rated Voltage 115V/250V
Rated Current 1~10A
Environmental Temperature 40°C
Temperature Range 25 / 085 / 21
Operating Frequency 50/60HZ
Line to Line 1450VDC
Line to Ground 2250VDC
Maximum Leakage Current 250VAC/60HZ 0.8mA Max
MOQ 100pcs
Price USD1~9.8/Meter
Lead Time 5~15 weekday

Features:

1. High performance and high attenuation power filters with IEC 320 socket

2. (R5) types comply with the requirements of IEC/EN60601-1 for safety clearance, leakage current and hipot testing

3. There are a variety of parts and combinations to meet different customer's EMC tests

Typical Applications:

-- Specially designed for LCD and PDP TV,medical applications,general electrical appliances

-- Medical equipment

-- Test and measurement equipment

-- Small and medium-sized machines and household equipment

Rule of Nomination:

YB 11 A12 - 10A - Q ( R 5 G )

¦ ¦ ¦ ¦ ¦ ¦ ¦

circuit case current connection optional

Tabulates:

Model No. Rated Current
@40°C
Terminal Options*

Bleeder resistor

(optional)


G
Leakage current 250V/50Hz Electrical Schematic Rated Voltage(V) Operating Frequency(Hz)
YB11A11-1A 1A Q - - - -

<0.8mA

Fig.1

115/250V

50/60Hz

YB11A11-2A 2A Q - - - - Fig.1
YB11A11-3A 3A Q - - - - Fig.1
YB11A11-4A 4A Q - - - - Fig.1
YB11A11-6A 6A Q - - - - Fig.1
YB11A11-8A 8A Q - - - - Fig.1
YB11A11-10A 10A Q - - - - Fig.1
YB11A11-15A 15A Q - - - - Fig.1
YB11A11-20A 20A Q - - - - Fig.1
YB11A12-1A 1A Q - - - - Fig.1
YB11A12-2A 2A Q - - - - Fig.1
YB11A12-3A 3A Q - - - - Fig.1
YB11A12-4A 4A Q - - - - Fig.1
YB11A12-6A 6A Q - - - - Fig.1
YB11A12-8A 8A Q - - - - Fig.1
YB11A12-10A 10A Q - - - - Fig.1
YB11A12-15A 15A Q - - - - Fig.1
YB11A12-20A 20A Q - - - - Fig.1
YB11A13-1A 1A Q - - - - Fig.1
YB11A13-2A 2A Q - - - - Fig.1
YB11A13-3A 3A Q - - - - Fig.1
YB11A13-4A 4A Q - - - - Fig.1
YB11A13-6A 6A Q - - - - Fig.1
YB11A13-8A 8A Q - - - - Fig.1
YB11A13-10A 10A Q - - - - Fig.1
YB11A13-15A 15A Q - - - - Fig.1
YB11A13-20A 20A Q - - - - Fig.1

Medical type Tabulates

Model No. Rated Current
@40°C
Terminal Options

Bleeder resistor

(optional)

Medical equipment
5

G
Leakage current 250V/50Hz Electrical Schematic Rated Voltage(V) Operating Frequency(Hz)
YB11A11-1A-x(R5) 1A Q S W 1 5 -

<5μA

Fig.2

115/250V

50/60Hz

YB11A11-2A-x(R5) 2A Q S W 1 5 - Fig.2
YB11A11-3A-x(R5) 3A Q S W 1 5 - Fig.2
YB11A11-4A-x(R5) 4A Q S W 1 5 - Fig.2
YB11A11-6A-x(R5) 6A Q S W 1 5 - Fig.2
YB11A11-8A-x(R5) 8A Q S W 1 5 - Fig.2
YB11A11-10A-x(R5) 10A Q S W 1 5 - Fig.2
YB11A11-15A-x(R5) 15A Q S W 1 5 - Fig.2
YB11A11-20A-x(R5) 20A Q S W 1 5 - Fig.2
YB11A12-1A-x(R5) 1A Q S W 1 5 - Fig.2
YB11A12-2A-x(R5) 2A Q S W 1 5 - Fig.2
YB11A12-3A-x(R5) 3A Q S W 1 5 - Fig.2
YB11A12-4A-x(R5) 4A Q S W 1 5 - Fig.2
YB11A12-6A-x(R5) 6A Q S W 1 5 - Fig.2
YB11A12-8A-x(R5) 8A Q S W 1 5 - Fig.2
YB11A12-10A-x(R5) 10A Q S W 1 5 - Fig.2
YB11A12-15A-x(R5) 15A Q S W 1 5 - Fig.2
YB11A12-20A-x(R5) 20A Q S W 1 5 - Fig.2
YB11A13-1A-x(R5) 1A Q S W 1 5 - Fig.2
YB11A13-2A-x(R5) 2A Q S W 1 5 - Fig.2
YB11A13-3A-x(R5) 3A Q S W 1 5 - Fig.2
YB11A13-4A-x(R5) 4A Q S W 1 5 - Fig.2
YB11A13-6A-x(R5) 6A Q S W 1 5 - Fig.2
YB11A13-8A-x(R5) 8A Q S W 1 5 - Fig.2
YB11A13-10A-x(R5) 10A Q S W 1 5 - Fig.2
YB11A13-15A-x(R5) 15A Q S W 1 5 - Fig.2
YB11A13-20A-x(R5) 20A Q S W 2 6 - Fig.2

Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service*Q: Fast-on 6.35x0.8mm Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service S: solder 4.0x0.8mm Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service W: UL1015 18awg

Electrical schematic:

Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service

Fig.1

Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service

Fig.2

Mechanical Dimension(Unit: mm)

Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service

Case A B C D E F G H I J K
A11 80.5 34 26 53 44 30 15.5 11.8 17 M3*0.5 6.35*0.8
A12 80.5 34 26 53 42 30 15.5 11.8 17 3.5 6.35*0.8
A13 80.5 34 26 53 42 30 15.5 11.8 17 3.5 6.35*0.8
Tolerances ±1 ±1 ±1 ±1 ±0.15 ±1 ±0.5 ±0.5 ±0.5 ±1 ±0.15

Insertion loss table(In 50ohm system according IEC/CISPR No.17)

Common mode -------- differential mode

16A 20A

Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service

Send your message to this supplier
Send Now

Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service

Ask Latest Price
Brand Name :
YBX
Model Number :
YB11A12-20A-Q
Certification :
cUL, TUV, CQC, CE, ROHS
Place of Origin :
China
MOQ :
100pcs
Price :
Negotiable
Contact Supplier
Yanbixin 20A Inline EMC Line Filter For Medical Equipment 120V 250V OEM Service

Shenzhen Yanbixin Technology Co., Ltd.

Verified Supplier
7 Years
guangdong, shenzhen
Since 2008
Business Type :
Manufacturer, Exporter
Total Annual :
10000000-1500000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement