Basic Parameters | | | | | | | | | | |||||||||
Battery cell | LifePO4 3.2V 200ah | | | | | | | | | |||||||||
Voltage out of factory | 47.8V-49.8V(40-60%) | | | | | | | | | |||||||||
Cycle life | 4000cycles ≥ 80% | | | | | | | | | |||||||||
Discharging Cut-off Voltage | 40V | | | | | | | | | |||||||||
Charing Cut-off Voltage | 58.4V | | | | | | | | | |||||||||
Inner resistance | ≤50mΩ | | | | | | | | | |||||||||
Standard charging current | 0.2C/40A | | | | | | | | | |||||||||
Standard discharging current | 0.2C/40A | | | | | | | | | |||||||||
Protective functions | over-charing/over-discharging/over-heat/shortcurcuit
| | | | | | | | | |||||||||
Communication port | RS485/CAN/RS232 | | | | | | | | | |||||||||
Working tempreture | Charge(charging):0~60℃ Discharge(charging):-20~60℃ | | | | | | | | |
We are a customized manufacturer, with a professional R & D design team and automated production lines.
We support one-to-one customization and can give you a satisfactory design according to the use.
Nominal Parameters | |
Model No | GA-D40KW |
Rated Voltage | 48V |
Rated Capacity | 800Ah |
Rated Power | 40KW |
Energy | 40.96KWH |
Max continouse charging current | 100A |
Size (L×W×H) | 530*542*1240mm |
Weight | 480kg |