When installing the machine, it is necessary to confirm the various environmental conditions. If the conditions are not met, erroneous actions may occur, damage the machine and reduce the service life of the machine.
Temperature: 0 ~ 40 C (ambient temperature during operation);
Humidity: 75% below (relative humidity), no condensation.
Altitude: below 1000 meters above sea level.
When the humidity is too high, the insulation condition will be poor, the parts will aging ahead of time, do not install the machine in the humid environment. Also do not install in dusty places or places with high concentration of organic gas and corrosive gas. Keep away from machinery such as welding machines which may cause electrical interference or have magnetic field.
Ground load analysis should be carried out by civil engineering experts. If the machine is installed on the reinforced concrete floor, the preparation of foundation before installation is generally not needed. If the machine is installed on the ordinary workshop floor, the corresponding foundation must be prepared. Pay attention to the machine installation must be based on the foundation map.
1). Parallelism between templates
Usually, the parallelism between fixed template and mobile template datum is up to standard, but due to improper transportation and installation, it may change, and it should be re-checked after installation. If the value exceeds the specified value.
Tolerance requirements for parallelism between fixed and mobile template mounting surfaces are shown in Table 9-2.
Table 9-2 Parallelism Tolerances
When the closing force of effective spacing of tie rod is zero, the closing force is maximum.
Over 200-2500.200.10
>250-400 0.240.12
>400-630.320.16
>630-10000.400.20
>1000-1600.480.24
>1600-2500.640.32