Electric Parameter | | | | | | | ||||||
Model: JW-B4S150A-779 | | | | | | | ||||||
NO. | Project | | Min. | Typ. | Max. | Unit | ||||||
1 | Voltage | Balance voltage for single cell | 3.175 | 3.200 | 3.225 | V | ||||||
2 | Current | Balance current for single cell | 50 | 55 | 60 | mA | ||||||
| | Current consumption | | | 70 | uA | ||||||
| | Maximal continuous charging current | | | 100 | A | ||||||
| | Maximal continuous discharging current | | | 100 | A | ||||||
3 | Over charge protection | Overcharge detection voltage for single cell | 3.625 | 3.75 | 3.775 | A | ||||||
| | Overcharge detection delay time | 500 | | 1500 | mS | ||||||
| | Overcharge release voltage for single cell | 3.50 | 3.55 | 3.60 | V | ||||||
4 | Over discharge protection | Overdischarge detection voltage for single cell | 2.25 | 2.30 | 2.35 | V | ||||||
| | Overdischarge detection delay time | 500 | | 1500 | mS | ||||||
| | Overdischarge release voltage for single cell | 2.4 | 2.5 | 2.6 | V | ||||||
5 | Overcurrent protection | Over discharge current protection | 230 | 280 | 330 | mS | ||||||
| | Detection delay time 1 | 500 | | 1500 | mS | ||||||
| | Detection delay time 2 | 500 | | 1500 | mS | ||||||
| | Overcharge current protects current | 100 | | 500 | A | ||||||
| | Detection delay time | 500 | | 1500 | mS | ||||||
6 | Short circuit protection | Short circuit protection current | | 500 | | A | ||||||
| | Detection delay time | 50 | | 800 | μS | ||||||
| | Protection condition | Exterior short circuit | | | | ||||||
| | Release condition | Cut load,Auto recovery | | | | ||||||
7 | Resistance | The on-state resistance of the main circuit | | | 5 | mΩ | ||||||
8 | Temperature Protection | Charging high temperature protection | 50 | 55 | 60 | ℃ | ||||||
| | Charge low temperature protection | | 0 | | ℃ | ||||||
| | Discharge high temperature protection | 70 | 75 | 80 | ℃ | ||||||
| | Discharge low temperature protection | -20 | -15 | -10 | ℃ | ||||||
| | Release condition | The temperature drops to 50ºC, charge release | | | | ||||||
9 | Temperature | Operating Temperature Range | -20 | / | 60 | ℃ | ||||||
| | Storage Temperature Range | -20 | / | 60 | ℃ | ||||||
10 | Break circuit protection | Disconnect the voltage sampling circuit to turn off the charge and discharge | Support | | | | ||||||
11 | NTC Protection | Thermistor temperature protection | Support | | | | ||||||
12 | Electronic switch | Electronic switch | Nonsupport | | | | ||||||
13 | Reverse polarity protection | | Support | | | |