Specifications
Brand Name :
DGBELL
Model Number :
BTL-D2-252/BTL-D2-288/BTL-D2-360
Certification :
CE/ISO
Place of Origin :
China
MOQ :
1 Set
Price :
Negotiation
Payment Terms :
Western Union, T/T, D/P, D/A, L/C
Supply Ability :
500 Sets per Month
Delivery Time :
Negotiation
Packaging Details :
Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual inside.
Keywords :
Climatic Test Chamber for Battery Cell
Power Supply :
AC 380V 50HZ
Temperature Range :
-40ºC — +150ºC
Temperature Fluctuation :
±0.3ºC
Cooling Rate :
Average 1.0°c/Min Full Rang
Heating Rate :
Average 1~3°c/Minute (Non-Linear No-Load)
Temperature Uniformity :
≤±2ºC(at No Load, Constant State)
Description

Features

1. Professional explosion-proof pressure relief design.

2. Professional high temperature smoke exhaust design.

3. Rich temperature monitoring and alarm mode.

4. Insulated and heat-resistant inner wall and partition.

5. Water-based and gas fire extinguishing firefighting linkage experience.

6. Design and guidance of sample layout and wiring.

7. Spray cooling water supply and drainage design.

8. Long-term operation of energy saving and consumption reduction design.

9. Consideration of integration with charging and discharging modules.

10. Better temperature uniformity.

11. Consistent low wind speed conditions.

2 Decks Battery Test Chambers ISO Approved For Temperature Climatic Detection

Application

Double-deck High Low Temperature Test Chamber provides a constant high and low temperature environment condition ranges from -40°C to 150°C (Available for customized design). It is widely used to test the thermal performance of various products and components. The two test cabinets work independently, providing high efficiency and performance for laboratory testing. Furthermore, the additional explosion-proof function enables this test chamber to be combined with the charge-discharge test, providing a temperature environment for various battery performance testing.

Features

  1. PLC Control, programmable, remote computer control
  2. Heating System
  3. Refrigeration System
  4. Forced Internal Circulate System
  5. Fume Exhaust System
  6. Explosion-proof System

Standards

  • IEC 60068-2-1:2007: Low temperature testing
  • IEC 60068-2-2:2007: High temperature testing
  • GJB 150.3-1986: High temperature testing
  • GJB 150.4-1986: Low temperature testing
  • GB/T 2423.1-2008: Low temperature testing
  • GB/T 2423.2-2008: High temperature testing
  • GB/T 31485-2015: Safety requirements and test methods for electric vehicles' power batteries

Performance parameters

Model

BTL-D2-252

BTL-D2-288

BTL-D2-360

Single Cabinet Inner Dimension

W600 X D700 X H600 MM

W800 X D600 X H600 MM

W1000 X D600 X H600 MM

External Dimension

W1300 X D1800 X H1950 MM

W1500*H1950*D1700 MM

W1740*H1900*D2100 MM

Structure Mode

An integral structure with upper and lower cabinets.

Temperature Range

-40ºC - +150ºC

Temperature Fluctuation

±0.3ºC

Heating Rate

Average 1~3°C/minute (non-linear no-load)

Cooling Rate

Average 1.0°C/min Full rang (non-linear no-load)

Temperature Uniformity

≤±2ºC(at no load, constant state)

Observation Window

Three-layer vacuum tempered glass

Test Terminal

12 sets of terminals are connected to the test cabinet inside and outside of the chamber

Cooling Mode

Air cooling / Water cooling (Optional)

Compressor

Tecumseh (France)

Controlling Mode

Touch screen programmable control PLC, with USB interface, with RS485 .interface can be connected to computer control, special network control software, convenient remote monitoring, data acquisition

Internal Chamber Material

1.0MM thick SUS304# stainless steel with mirror finish, sprayed with Teflon insulation

External Chamber Material

1.2 MM thick Galvanized sheet, dusting pained with high temperature plasticized coating.

Power Supply

AC380V 50HZ 12KW/14KW/16KW

Safety Protection

Automatic explosion-proof pressure relief device, explosion-proof chain, tri-color light alarm device, remote control, smoke exhaust device, fire extinguishing device, etc.

Extension Function

Provide communication protocol, able to accompanied use with charge and discharge machine

Use common sense of high and low temperature test chamber

  1. The enclosure of the high and the low test chamber must be grounded during installation. If the high and low temperature test chamber is not grounded, there will be a risk of electric shock in case of leakage.
  2. Do not run the high and low temperature test chamber before it is installed, and make sure that the installation is reliable before performing the test.
  3. If heating samples are placed in the test chamber, please use an external power supply for the sample control power supply, do not use the power supply of this test chamber directly.
  4. The operation of the cabinet will produce a dangerous current, non-professionals should not open the cover of the electric control cabinet.
  5. If the high and low temperature test chamber is not equipped with humidification function, pay attention to the difference in use and requirements when reading the instructions.
  6. When the test chamber is running, various motors and fans are started according to instructions under the control of the controller. Do not touch the components that are temporarily in a static state with your hands to prevent the components from starting suddenly and causing personal injury. It is indeed necessary to approach the rotating parts, please cut off the main power switch and ensure that the protective device is in good condition when working at the place.
  7. It is forbidden to move the test chamber when there is a sample inside, otherwise, the sample may reverse or fall.
  8. Before use, make sure that the high and low temperature test chamber is fixed, the casters are off the ground to adjust the foot to the ground, otherwise, the test chamber will accidentally move when subjected to the external force.
Send your message to this supplier
Send Now

2 Decks Battery Test Chambers ISO Approved For Temperature Climatic Detection

Ask Latest Price
Watch Video
Brand Name :
DGBELL
Model Number :
BTL-D2-252/BTL-D2-288/BTL-D2-360
Certification :
CE/ISO
Place of Origin :
China
MOQ :
1 Set
Price :
Negotiation
Contact Supplier
video
2 Decks Battery Test Chambers ISO Approved For Temperature Climatic Detection
2 Decks Battery Test Chambers ISO Approved For Temperature Climatic Detection

Guangdong Bell Experiment Equipment Co., Ltd

Active Member
5 Years
guangdong, dongguan
Since 2005
Business Type :
Manufacturer, Seller
Total Annual :
10000000-100000000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier