Walk in Environmental Test Chamber for Battery Altitude Simulated Test
Test Object: battery pack and system
Test Conditions: Altitude 4000m or the equate air pressure condition, atroom temperature.
The test objects stay in the test condition as Item 2 for 5 hours.
Subject the test object to 1C(no more than 400A) constant current discharge until reaching the cutoff condition.
After testing, observe for 2h under the room temperature.
UN 38.3
Product Name | Altitude Simulated Test Chamber | |
Model | BE-8203-5m³ | BE-8203-12m³ |
Internal Dimension | W1600 X D2400 X H1300mm | W2000 X D3000 X H2000mm |
External Dimension | W2050 X D2700 X H2200mm | W2450 X D3300 X H2900mm |
Equipment weight | Approx 6 ton | Approx 9ton |
Power Supply | AC 380V,6.0KW | AC 380V,8.0KW |
Pressure Range | 10.0KPa—101.3KPa (Adjustable) | |
Pressure Reducing Time | Less than 30 min | |
Pressure Recovery Time | Less than 30 min | |
Pressure Maintenance | ≧10 hours | |
High Tension Terminal | 4 pieces, Max. DC 500A,1000V | |
Low Tension Terminal | 4 pieces, Max. DC 500A,1000V | |
Data Cable Interface | 2 groups, DB9 line | |
Observe Window | W400 X H600 mm | |
Auto Door | Adopt hydraulic automatic open design | |
Inner Material | SUS304# stainless steel+45# steel | |
External Material | SECC steel plate,powder painted | |
Power Supply | AC 380V,6.0KW | |
Other Requirement | PLC touch screen control + computer remote control. |