Specifications
Brand Name :
DGBELL
Model Number :
BE-8103
Certification :
CE/ISO
Place of Origin :
China
MOQ :
1pcs
Price :
Negotiation
Payment Terms :
T/T, Western Union, L/C, D/A, D/P
Supply Ability :
100 Sets per Month
Delivery Time :
Negotiation
Packaging Details :
Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual inside.
Keyword :
Lab Thermal Abuse Test Equipments
Controlling Accuracy :
±0.5℃
Temperature Deviation :
±2.0℃, No load
Heating Rate :
RT~150°C (Linear 5°C/min)
Control Display :
PLC touch type (7 inch) + remote control
Working Cabinet Dimension :
W600XD500XH600 mm
External Dimension :
W940XD780XH1620 mm
Description

Thermal Abuse Test Chamber for Battery Cell

Standards

1. IEC 62133-2017

2. UL 1642

3. GB 31241-2014

Main technical parameters

Model

BE-8103

Structure

All-in-one structure, the door uses explosion-proof lock + explosion-proof chain


Normal temperature to 150°C (Adjustable)

Temperature Range

Controlling Accuracy

±0.5℃

Temperature Deviation

±2.0℃, No load

Heating Rate

RT~150°C (Linear 5°C/min)

Control Display

PLC touch type (7 inch) + remote control

Working Cabinet Dimension

W600XD500XH600 mm

External Dimension

W940XD780XH1620 mm

Inner Chamber Material

SUS304 Stainless steel with mirror-finish

External Chamber Material

SECC steel plate, fine powder paint coating (thickness 1.5mm)

Bottom

With universal wheel

Observation Window

390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh)

Insulation Material

Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time

Terminal Hole

Diameter 50mm Terminal hole on the left and right sides

Power Supply

220V / 50HZ / 4.0KW

USB Interface

With USB interface, the test data can be exported

Auxiliary Function

Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch

IEC 62133-2017 Thermal Abuse Test Chamber For Battery Cell

The heating test of battery thermal abuse test chamber shall be carried out as follows

A: Relevant standard test requirements

Single battery safety test

The heating test is carried out as follows:

1. The single battery is charged according to the method of 6.1.3

2. Put the single battery into the temperature chamber.

3. For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.

4. For nickel metal cyanide batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.

5. Observe for 1h.

B: Battery module safety test

1. The battery module battery shall be charged according to the method in 6.1.4.

2. For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.

3. For nickel metal cyanide batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.

4. Observe for 1h.

Send your message to this supplier
Send Now

IEC 62133-2017 Thermal Abuse Test Chamber For Battery Cell

Ask Latest Price
Watch Video
Brand Name :
DGBELL
Model Number :
BE-8103
Certification :
CE/ISO
Place of Origin :
China
MOQ :
1pcs
Price :
Negotiation
Contact Supplier
video
IEC 62133-2017 Thermal Abuse Test Chamber For Battery Cell

Guangdong Bell Experiment Equipment Co., Ltd

Active Member
5 Years
guangdong, dongguan
Since 2005
Business Type :
Manufacturer, Seller
Total Annual :
10000000-100000000
Employee Number :
100~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement