Resistant to both high and low temperatures monolithic material Epoxy worktops
Description:
Onus is our brand. We have professional formula, our leading technology can meet domestic and overseas markets' requirment, expertises in our company will provide perfect suggestion and good solution for your project.
Advantages:
1.Corrosion resistance
It has superior corrosion resistance to acid and alkali solvents commonly used in laboratory.
2.Durable
It is absolute moisture-proof, and no pore, and it will not delaminate, expand and deform.
Specification:
Chemical Test Results for Black | ||
No. | Chemical Reagent | Actual Rating |
1 | Acetate,Amyl | 1 |
2 | Acetate,Ethyl | 1 |
3 | Acetic Acid,98% | 1 |
4 | Acetone | 1 |
5 | Acid Dichromate,5% | 0 |
6 | Alcohol,Butyl | 0 |
7 | Alcohol,Ethyl | 0 |
8 | Alcohol,Methyl | 1 |
9 | Ammonium Hydroxide,28% | 0 |
10 | Benzene | 0 |
11 | Carbon Tetrachoride | 1 |
12 | Chloroform | 1 |
13 | Chromic Acid,60% | 1 |
14 | Cresol | 0 |
15 | Dichlor Acetic Acid | 0 |
16 | Dimethylformanide | 0 |
17 | Dioxane | 0 |
18 | Ethyl Ether | 0 |
19 | Formaldehyde,37% | 0 |
20 | Formic Aicd,90% | 0 |
21 | Furfural | 0 |
22 | Gasoline | 0 |
23 | Hydrofluoric Acid,37% | 1 |
24 | Hydrofluoric Acid,48% | 3 |
25 | Hydrogen Peroxide,30% | 0 |
26 | Lodine,Tincture of | 0 |
27 | Methyl Ethyl Ketone | 0 |
28 | Methylene Chloride | 1 |
29 | Mono Chlorobenzene | 1 |
30 | Naphthalene | 0 |
31 | Nitric Acid,20% | 0 |
32 | Nitric Acid,30% | 0 |
33 | Nitric Acid,70% | 0 |
34 | Phenol,90% | 0 |
35 | Phosphoric Acid,85% | 0 |
36 | Silver Nitrate,Saturated | 0 |
37 | Sodium Hydroxide,10% | 0 |
38 | Sodium Hydroxide,20% | 0 |
39 | Sodium Hydroxide,40% | 0 |
40 | Sodium Hydroxide,Flake | 0 |
41 | Sodium Sulfide,Saturated | 0 |
42 | Sulfuric Acid,33% | 0 |
43 | Sulfuric Acid,77% | 0 |
44 | Sulfuric Acid,96% | 3 |
45 | Sulfuric Acid,77% and Nitric Acid 70%, equal parts | 0 |
46 | Toluene | 0 |
47 | Trichloroethylene | 1 |
48 | Xylene | 0 |
49 | Zinc Chloride, Saturated | 0 |
Rating scale: | Level 0--No detectable change | |
Level 1--Slight change in color or gloss | ||
Level 2-- Slight surface ething or severe staining | ||
Level 3--Pitting,cratering,swelling, or erosion of coating.Obvious and significant deterioration | ||
Acceptance level: | Laboratory grade finishes shall result in no more than four level 3 conditions. Suitability for a given application is dependent upon the chemicals used in a given laboratory |
Thanks for visiting, more information please contact with us.