Specifications
Brand Name :
TSTLP
Model Number :
TS-EX24
Place of Origin :
Guangzhou
Certification :
CE Compliance
MOQ :
Negotiable
Price :
Negotiable if good quantity
Packaging Details :
By standard export box/carton
Delivery Time :
Around 7 working days upon receipt of payment
Payment Terms :
100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead
Supply Ability :
2000 sets/month
Un :
24V
Uc :
32V- / 22.5~
Iimp :
1.5kA
IL :
0.55A
In :
10kA
fG :
67MHz
Enclosure Material :
Stainless Steel Case
Compliance :
IEC-61643-21 / GB18802.21 / YD/T 1542
Description

Hazardous area surge protection device for 4-20mA measuring control & bus system

Installed at LPZ OB-2 or higher inside the control equipment, the built-in cable connected with the control equipment’s wiring terminal. TS-24 hazardous area surge protection device is available to apply in intrinsically safe circuit in hazardous areas and 4-20mA measuring control system and bus system.

  • Technical Data of TS-EX24 Hazardous area surge protection equipment
Model Number TS-EX24
Normal Voltage Un 24V-
Rated voltage (max. continuous voltage) Uc

32V-

22.6V ~

Lightning impulse current (10/350) Iimp 1.5kA
Normal current IL 0.55A
Nominal discharge current (8/20) In 10kA (per line); 10kA(total)
Voltage protection level at In Up ≤ 58V (line/line); ≤ 1700V (line/PG)
Voltage protection level at 1kV/μs Up ≤ 50V (line/line); ≤ 1200V (line/PG)
Bandwidth fG 67MHz
Capacitance C ≤ 25pF (line/line); ≤ 15pF (line/PG)
Operating temperature range -40 0C ~ +80 0C
Mounting in M20 x 1.5 screws
Connection (input / output) 1.3 mm x 250mm length of the connecting lead
Earthing via Connecting lead
Enclosure material Stainless steel case
Compliance IEC-61643-21, GB18802.21, YD/T 1542

  • MAIN CHARACTER
  1. Small & easy replacement.
  2. Easy to install inside the control equipment.
  3. Stainless steel housing, fireproof & explosion-proof outdoor use.

Installation Instruction

  • Screwing into the wiring port of the control equipment directly
  • Blue wire connecteed with signal port “+”, Black Wire connected with signal port “-”
  • Yellow / Green wire connect with grounding port “GN” of grounding system.
  • After installation, check if commuication is be operating normally.

Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD.

INSTALLATION DIAGRAM

Hazardous Area Surge Protection Equipment For 4-20mA Measuring Control And Bus System

WARNING:

  • The hazardous area surge protection device must be installed by electrically skilled person, conforming to national standards and safety regulations.
  • It is recommended that installation should be done under power off condition.

PDF Catalog Download - TS-EX24 SPD for Hazardous ...

Tag: hazardous area surge protection, hazardous area surge protection device

Send your message to this supplier
Send Now

Hazardous Area Surge Protection Equipment For 4-20mA Measuring Control And Bus System

Ask Latest Price
Brand Name :
TSTLP
Model Number :
TS-EX24
Place of Origin :
Guangzhou
Certification :
CE Compliance
MOQ :
Negotiable
Price :
Negotiable if good quantity
Contact Supplier
Hazardous Area Surge Protection Equipment For 4-20mA Measuring Control And Bus System
Hazardous Area Surge Protection Equipment For 4-20mA Measuring Control And Bus System
Hazardous Area Surge Protection Equipment For 4-20mA Measuring Control And Bus System

TS Lightning Protection Co.,Limited

Active Member
7 Years
guangdong, heyuan
Since 2013
Business Type :
Manufacturer, Exporter
Total Annual :
5,000,000-6,000,000
Employee Number :
150~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement