Specifications
Certification :
ISO9001
Place of Origin :
China
MOQ :
10PCS
Payment Terms :
D/A, D/P, T/T, Western Union, MoneyGram,Paypel
Supply Ability :
10000 piece /Month
Delivery Time :
7-10 working days by DHL,EMS,Container ets
Packaging Details :
1 in box,50 boxes in a carton
Brand Name :
EST
Model Number :
PS-I01GK
Type :
Elevator parts
Usage for :
elevator
Keywords :
Elevator light curtain
Power supply :
AC/DC 24V
Original place :
China
Business Type :
manufacturer
Model :
SFT-824/834
MOQ :
10 SETS
Brand :
SFT
Description

PS-I01GK Instructions for the use of elevator floor sensor devices

This device is suitable for all need to PNP-type level sensor signal elevator, the device to overcome the photoelectric and traditional
flat-layer switch inherent vulnerability of the shortcomings, high reliability and precision and fast response capability, low price Very high price.

Main characters:

1. Output high level is 23.2V, low level is 0V, load current is large, wide application range.

2. The output signal is square wave pulse signal, fast response and reliable, easy to host the signal processing.

3. Ultra-low current consumption: 15mA, product life long.

4. The circuit has a power supply reverse protection, output short circuit protection and prevent malfunction and other protection functions.

5. Circuit with anti-± 6KV high voltage static, ± 4.5Kv group pulse and surge protection.

6. Electrical performance in line with "International Electrotechnical Commission (IEC)" standard requirements;

7. High reliability, small size, installation and commissioning is very convenient. Simple structure, low price.

Technical Specification:

Application Range: Applicable to all need to PNP-type level switch signal elevator
Response time 4ms
Current consumption 15mA
4 Load current 120mA
5. Output form: PNP switch signal: no metal into the sensor area; output 0v low; a metal into the sensor area when the output high.
6 Working temperature: -25~55℃
7 Working environment humidity 35%~85%RH
8 Power supply: DC 24V(±5%),Machine operating current≤100mA
9. Protection class IP53
10 Withstand voltage 1000V ,50Hz,1 minute
11 Insulation resistance DC500V,≥20MΩ,
12 Install Position: The elevator car is close to the partition board
13 Overall Size:

100mm*65mm*25mm

Working Principle:

During the operation of the elevator, the system is based on the installation of the elevator shaft into the sensor area of the induction sensor area, the magnetic
plate produced by the eddy current effect, weaken the electromagnetic field within the sensing area, so that the device sensor internal oscillation circuit stop Vibration,
through the signal processing and amplification of a 23.2v high-level pulse signal; when the isolation plate from the layer sensor sensor area, the induction area of the
electromagnetic field back to normal, the oscillation circuit to start again, the product output low , Thereby achieving the determination of the position of the elevator
car and the purpose of reaching the elevator deck

Product appearance and electrical wiring diagram:

Elevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTDElevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD

l System wiring principle:

No. Cable color Wiring instructions
1 (Brown) +DC24V
2 (Blue) Com
3 (Black) Signal output

Never connect the device's output cable directly to an external power supply, which may cause permanent damage.

Installing Method:

Elevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTDAdjustment:

⒈First of all, according to the hoistway inside the magnetic disk bracket bracket installed on the magnetic plate, and then installed in the straight beam position of the
device fixed bracket. Finally, adjust the position of the leveling sensor according to the position of the magnetic plate, make sure that the partition plate is in the center
of the sensing area of the device. The partition plate can not damage the device during the operation of the elevator.

2. After securing the installation position, connect the product terminals according to the above system wiring principle. One end is connected with the main unit and one
end is connected to the output port of the unit. ,

3. In the process of moving up and down the elevator, the magnetic plate into the device sensing area, the product indicator light will be red, the output high, separated
from the device sensing area, the product indicator light off, the output low The At this point, the product into the normal working state debugging is completed.

other:

Instruction Manual:1 set

Tighten the screws(M5*30) 2sets

If the system is abnormal during debugging or use, please contact us directly.


Products photo show:

Elevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD



Elevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD

Contact Person:Miss Yolly
Website:www.estlift.com/www.est-lift.com
E-mail:yollyapple@163.com

sales01@xaest.com

Skype:yollyapple
Wechat:YollyApple

Whatsapp&Mobile:+86 189 9286 2361
Tel:+86-029 8841 6613-808

Fax:+86-029 8556 5714-886

Send your message to this supplier
Send Now

Elevator safety parts of leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD

Ask Latest Price
Certification :
ISO9001
Place of Origin :
China
MOQ :
10PCS
Payment Terms :
D/A, D/P, T/T, Western Union, MoneyGram,Paypel
Supply Ability :
10000 piece /Month
Delivery Time :
7-10 working days by DHL,EMS,Container ets
Contact Supplier
Elevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD
Elevator safety parts of  leveling switch PS-I01GK from XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD

XI'AN EXCELLENT ELECTROMECHANICAL CO.,LTD

Site Member
10 Years
Shaanxi
Since 2006
Business Type :
Manufacturer
Certification Level :
Site Member
Contact Supplier
Submit Requirement