Plenum Cat6 U/Utp Cmp Lan Cable Can Pass Fluke 1800 Test Drum 10g At 500mhz Communication Cable
STANDARD COMPLIANCES
• ANSI/TIA 568-C.2
• ANSI/TIA 862 (Building Automation)
• ISO/IEC 11801 Ed. 2.0 (Class EI)
• ICEA 8-102-700 (Category 6 or 5E)
• REACH Compliant • CPR Compliant (Fully Comply to 305/2011 & EN 50575:2014-09)
• RoHS Compliant Directive 2002/95/EG
DESCRIPTION
• 23 AWG 4 Pair U/UTP 10G Category 6A cable tested to ANSI/TIA 568-C.2 for 10Gbps @500Mhz premium grade, high performance for top level network cabling for maximum headroom and bandwidth. Available in Wood Reel for easier installation.
CONSTRUCTION
Conductor | Solid Bare Copper |
AWG | 23 |
Conductor Dia. (+/-0.005mm) | 0.55 |
Jacket | PVC (CMP) |
Outer Dia.(±0.20mm) | 5.8 |
COLOR
The color of the wire pair in cables |
A:Blue-White with Blue |
B:Orange-White with Orange |
C:Brown-White with Brown |
D:Green-White with Green |
ELECTRICAL CHARACTERISTICS
1.0-100MHz Impedance (ohms) | 100 ± 12 |
100-350MHz Impedance (ohms) | 100 ± 15 |
350-600.0MHz Impedance (ohms) | 100 ± 22 |
Delay SKEW: | 25ns/100M (MAX) |
Max. Propagation Delay: | 534+36 ns/100m |
Pair-to-Ground Capacitance Unbalance (pF/100m) | <=330 |
Max. Conductor DC Resistance 20oC (ohms/km) | 93.8 |
Resistance Unbalance (%) | <=3.5 |
Nominal velocity of propagation(NVP) | 72% |
MECHANICAL PROPERTIS
Test Object | Jacket | ||
Test Material | PVC | ||
Before | Tensile Strength (Mpa) | >=13.8 | |
Aging | Elongation (%) | >=100 | |
Aging Condition (oCxhrs) | 100x168 | ||
After | Tensile Strength (Mpa) | >=75% of unaged | |
Aging | Elongation (%) | >=75% of unaged | |
Cold Bend(-20±2oCx4hrs) | No crack | ||
300hours weatherometer test | PASS |
Transmission properties
Frequency | Return loss | Attenuation | NEXT | ACRF |
(MHz) | (Min dB) | Max (dB/100m) | (Min dB) | (dB/100m) |
1 | 20.0 | 2.1 | 74.3 | 71.8 |
4 | 23.0 | 3.8 | 65.3 | 59.8 |
8 | 24.5 | 5.3 | 60.8 | 53.7 |
10 | 25.0 | 5.9 | 59.3 | 51.8 |
16 | 25.0 | 7.5 | 56.2 | 47.7 |
20 | 25.0 | 8.4 | 54.8 | 45.8 |
25 | 24.3 | 9.4 | 53.3 | 43.8 |
31.25 | 23.6 | 10.5 | 51.9 | 41.9 |
62.5 | 21.5 | 15.0 | 47.4 | 35.9 |
100 | 22.0 | 19.1 | 44.3 | 31.8 |
200 | 20 | 27.6 | 43.8 | 25.8 |
250 | 19.3 | 31.1 | 42.3 | 23.8 |
300 | 18.8 | 34.3 | 41.1 | 22.3 |
400 | 18.0 | 40.1 | 39.3 | 19.8 |
500 | 17 | 45.3 | 37.8 | 17.8 |
600 | 16.6 | 50.1 | 36.6 | -- |
750 | 16 | 56.8 | 35.2 | -- |
Frequency | PSNEXT | ELFEXT | Delay | -- |
(MHz) | Min (dB) | Min (dB/100m) | Max (ns/100m) | |
1 | 72.3 | 71.8 | 570.0 | |
4 | 63.3 | 59.8 | 552.0 | |
8 | 58.8 | 53.7 | 546.7 | |
10 | 57.3 | 51.8 | 545.4 | |
16 | 54.2 | 47.7 | 543.0 | |
20 | 52.8 | 45.8 | 542.0 | |
25 | 51.3 | 43.8 | 541.2 | |
31.25 | 49.9 | 41.9 | 540.4 | |
62.5 | 45.4 | 35.9 | 538.6 | |
100 | 42.3 | 31.8 | 538.0 | |
200 | 41.8 | 25.8 | 537 | |
250 | 40.3 | 23.5 | 536 | |
300 | 39.1 | 22.3 | 536 | |
400 | 37.3 | 19.8 | 536 | |
500 | 35.8 | 17.8 | 536 | |
600 | 34.6 | -- | -- | |
750 | 33.2 | -- | -- |
FEATURES AND BENEFITS
• Category 6A performs at improved specifications, particularly in the area of alien crosstalk. Category 6A make use of their higher standards by allowing full 10GBASE-T transmission speeds of up to 10Gbps, at 500MHz of signal bandwidth, over 100 meters (330 ft)
• Improved cable temperature rating (750 C Plenum) for greater protection against increased operating temperatures and for high-wattage applications
• The internal separator optimizes each pair for superior electrical performance and maintains flexibility. This unique spline stabilizes each pair to create a smaller, round cable profile
APPLICATIONS
• IEEE 802.3 10G Base-T, 1000Base-T, 100Base-TX, 10Base-T, PoE, PoE+ • ANSI/TIA 854: 1000Base-TX
• CDDI, Token Ring, ATM
• Digital Video
• Broadband and Baseband Analog Video