Wall Mounted Car EV Wall Box Home Charging Station For Electric Vehicle Car
All products must pass the following inspection before leaving the factory:
1. Function test:
A. charging function control test,
B. communication function test,
C. insulation detection function test,
D. vehicle plug locking function test,
E. pre-charging function test
2. Charging output test:
A. four ui large constant power output test,
B. power control test,
C. low-voltage auxiliary power test,
D. output current response time test,
E. transmission out current stopping rate test,
F. efficiency test,
G. power factor test.
Wall Mounted EV Charger Power Specification
|
|||
|
EU Standard
|
||
Charging Connector Type
|
IEC 62196-2 (Type 2)
|
||
AC Power Input Rating
|
1 Phase
|
3 Phase
|
|
230V±15%
|
380V±15%
|
||
AC Power Output Rating
|
3.5kw/16A
|
11kw/16A
|
|
7kw/32A
|
22kw/32A
|
||
|
43kw/63A
|
||
Frequency Rating
|
50/60 Hz
|
||
User Interface & Control
|
|||
Emergency Stop Button
|
Yes
|
Plug-and-Charging
|
Yes
|
RFID Card Charging
|
Yes
|
App Charging
|
Yes
|
Ethernet Interface
|
Yes
|
Wifi Function
|
Yes
|
OCPP Protocol
|
OCPP 1.6
|
4.3-inch LCD Screen
|
Optional
|
Protection
|
|||
Over Voltage Protection
|
Yes
|
Under Voltage Protection
|
Yes
|
Over Load Protection
|
Yes
|
Short Circuit Protection
|
Yes
|
Earth Leakage Protection
|
Yes
|
Ground Protection
|
Yes
|
Over-temp Protection
|
Yes
|
Surge Protection
|
Yes
|
RCD
|
Type B
|
|
|
Environmental
|
|||
Storage Temperature
|
-40 ~ 75℃
|
Operating Temperature
|
-30 ~ 55℃
|
Operating Humidity
|
Up tp 95%, non-condensing
|
Altitude
|
≤2000m
|
Cooling Method
|
Natural Cooling
|
|
|
M3P Wallbox Mechanical
|
|||
IP Code
|
IP54
|
Dimension(H×W×D,mm)
|
410×260×164
|
Weight
|
12kg
|
Charging Cable Length
|
5m or Customize
|
Enclosure Material
|
Front-panel: Tempered Glass, Back-cover: Plate Metal
|
||
M3T Mounting Pole(Optional)
|
|||
Dimension(H×W×D,mm)
|
1400×200×100
|
Weight
|
<8kg
|
Enclosure Material
|
Metal
|