Normal operation of the environmental requirements
1. Working environment temperature: - 30 ℃ ~ + 50 ℃
2. Storage temperature: - 40 ℃ ~ + 70 ℃
3. Relative humidity: 5% ~ 95%
4. The installation of vertical orientation degree: 5% or less
5. Install operating altitude: 2000 meters or less
6. Use place no strong vibration and impact, no strong electromagnetic
7.Input power voltage range: three-phase 400V±20%
8.Insulation resistance:>10MΩ
9.Material anti-fire feature:UL94-V0
10.Working humidity:0~95%
EV Charger Station Features:
Model Name | EVC10-07C1S | EVC10-07C1C | EVC10-22C1S | EVC10-22C1C | |
Input Rating | 230±10%Vac (One Phase) | 400±10%Vac (Three Phase) | |||
Frequency | 50Hz | ||||
Input Current | 32A | ||||
Output Current | 32A | ||||
User Authentication | RFID (ISO 14443) | ||||
External | LAN (optional) + 4G (optional) or Wi-Fi (optional) | ||||
Internal | OCPP 1.6 JSON (OCPP 2.0 compatible) | ||||
Operating Temperature | -22˚F~122˚F(-30˚C~50˚C) | ||||
Humidity | Max. 95% RH | ||||
Altitude | ≦ 2000m | ||||
IP Level | IP 54 | IP65 for box | IP 54 | IP65 for box | |
Dimension(WxDxH) | 350x250x175mm (13.8″x9.8″x6.9″) | 350x250x130mm (13.8″x9.8″x5.1″) | 350x250x175mm (13.8″x9.8″x6.9″) | 350x250x130mm (13.8″x9.8″x5.1″) | |
Charging Outlet | One Socket | 5M Cable | One Socket | 5M Cable | |
RCD | RCD TYPE B | ||||
Charging Interface | Type 2 Plug | ||||
Multiple Protection | Over current, Under voltage, Over voltage, Residual current, Surge protection, Short circuit, Over temperature, Ground fault, Current leakage protection |