DC Fast Charging Station EV Charger 60kW with GBT and CCS Combo 2 Plugs OCPP JSON 1.6 2.0
model | 3P60K-D1-100A-EU01 | ||||
---|---|---|---|---|---|
enter | Input rated voltage and current | 400V 3ph 125A max. | |||
number of input lines | 3ph / L1, L2, L3, PE | ||||
power factor | >0.98 | ||||
current total harmonics | <5% | ||||
efficiency | >95% | ||||
output | Output rated power | 60kW | |||
The output voltage | 200V-750V DC | ||||
Protect | Protection method | Overcurrent, undervoltage, overvoltage, residual current, lightning protection, short circuit, overtemperature, ground fault | |||
User Interface and Control | show | 7” touch screen | |||
Supported languages | English and other languages (based on need) | ||||
charging options | Auto recharge, time based, energy based, cost based | ||||
charging interface | GB and CCS2 | ||||
User authentication method | RFID / NFC / QR code (two-dimensional code) | ||||
communication | Communication method | Ethernet (standard); Wi-Fi, 4G (optional) | |||
OCPP Compliant | OCPP1.6 / OCPP2.0 | ||||
environment | Operating temperature | -20°C to +55°C (Derating over 55°C) | |||
Storage temperature | -40°C to +70°C | ||||
humidity | < 95% RH, non-condensing | ||||
altitude | up to 2000 m (6000 feet) | ||||
mechanical | Protection class | IP54 | |||
Shell shock resistance rating | IK10 according to IEC 62262 | ||||
cooling method | forced air cooling | ||||
Charging cable length | 7m | ||||
Dimensions (W*D*H) mm | 650*700*1500 | ||||
weight | 320kg | ||||
rule | Certification / Compliance | CE / EN 61851-1/-23 / GB 18487.1, GB/T 27930, NB/T 33001, NB/T 33008.1 |