Specifications
Brand Name :
ANS
Model Number :
ANS-RCD-63A
Certification :
TUV,CE
Place of Origin :
China
MOQ :
1pc
Price :
USD
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
1000pcs a day
Delivery Time :
20-30days
Packaging Details :
standard export package
Product name :
63A RCD Circuit Breaker
Rated Current :
63A
Poles :
2Pole (1P+N) , 4Pole (3P+N)
Rated voltage :
2Pole: 230V/240V , 4Pole: 400V/415V
Rated frequency :
50/60Hz
Rated residual operation current :
30mA
Short-circuit current Inc :
Ic 10000A
Standard :
IEC 61008-1, IEC 62423
Description

40A 4 Pole 30mA Type B 10KA Residual Current RCD Circuit Breaker

What are RCDs?

Residual Current Devices (RCDs) are safety switching devices. They are designed to provide safety for three types of protection;

  1. Fault Protection. Any tripping current dependent on the resistance of the earth path.
  2. Additional Protection. RCDs not exceeding 30 mA tripping current.
  3. Fire Protection. A tripping current not exceeding 300 mA.

Specification

Type(wave form of the earth leakage sensed) B Type RCCB
Rated current In
63A
Poles 4P
Rated voltage Ue
2P 240V~,4P 415V~
Insulation voltage Ui 500V
Rated frequency 50/60Hz
Rated residual operation current(I n) 30mA
Rated residual making and breaking capacity (I m)
500A(In≤40A), 10In(In>40A)
Short-circuit current Inc= I c 10000A
SCPD fuse 10000
Break time under I n ≤0.1s
Rated impulse withstand voltage(1.5/50) Uimp 4000V
Dielectric test voltage at ind.Freq. for 1min 2.5kV
Electrical life 2,000 Cycles
Mechanical life 4,000 Cycles

Installation

Contact position indicator Yes
Protection degree IP20
Ambient temperature(with daily average≤35°C) -5°C~+40°C
Storage temperature -25°C~+70°C
Terminal connection type Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable 35mm2 18-3AWG
Terminal size top/bottom for busbar 35mm2 18-3AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection
Power supply in both directions

Tripping Current Range

Tripping
Lagging Angle
I△n>0.01A
I△n≤0.01A
Current
0.35I△n≤I△≤1.4I△n
0.35I△n≤I△≤2I△n
Range
90°
0.25I△n≤I△≤1.4I△n
0.25I△n≤I△≤2I△n
135°
0.11I△n≤I△≤1.4I△n
0.11I△n≤I△≤2I△n

Detectable wave form Pulsating direct current sensitive Surge current proof
B class
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents,alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents,whether applied suddenly or increasing slowly.
4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker
They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.
4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker
RCCB’s surge capacity.
Not tripping at standardized 8/20 υs surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

Circuit Diagram

4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

What are the effects of DC residual fault current on RCDs?
it might be worth thinking about some older models of earth fault loop impedance testers, which could cause the RCD to operate unintentionally. To prevent this, some types of earth fault loop impedance testers imposed a DC current on the AC test current. This DC current saturated the magnetic core of the RCD preventing it from tripping under the test condition.

Where equipment produces an element of residual DC, for example, variable-speed drives is connected to the electrical installation, the DC component can saturate the magnetic core and effectively blind or locks the RCD. This is known as ‘blinding’ and could either prevent the RCD from operating or reduce the sensitivity resulting in a dangerous situation.

Application

Construction sites

Agricultural and horticultural premises

Conducting locations with restricted movement

Caravan and camping parks

Exhibition shows and stands

Outdoor lighting

Marinas

Medical locations

Solar Photovoltaic system power supplies

Mobile or transportable units

Electric vehicle charging installations

Temporary installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses, and

Floor and ceiling heating systems.

Certification:TUV

4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

Send your message to this supplier
Send Now

4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

Ask Latest Price
Brand Name :
ANS
Model Number :
ANS-RCD-63A
Certification :
TUV,CE
Place of Origin :
China
MOQ :
1pc
Price :
USD
Contact Supplier
4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker
4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker
4 Pole RCD Circuit Breaker 415V 63A 3 Phase Circuit Breaker

Chengdu Honors Technology Co.,Ltd

Verified Supplier
5 Years
chengdu
Since 2019
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Total Annual :
2000000-5000000
Employee Number :
15~40
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement