IEC60068-2-30 Walk-in Humidity and Temperature Controlled Chamber 22m³
Complied Standards & Clauses
IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
Product information:
This equipment is suitable for environmental simulation reliability tests of various electrical and electronic products and other products, parts and materials, such as constant high and low temperature, gradual change, and cycle tests.
Safety test restrictions:
A) Test and storage of samples of flammable, explosive and volatile substances
B) Test of corrosive substance samples,test and storage of biological samples
C) Test and storage of strong electromagnetic emission source samples
Technical Parameters
Product name | Walk-in Constant Temperature and Humidity Test Chamber |
Mode | SN881-22m3 |
Effective volume | 22m³ |
Inner box size | W4500 mm*H2270 mm*D2200mm |
Outer box size | About W5100 mm*H3700 mm*D2800 mm(Excluding unit size) Reminder: Please refer to the final design and confirm the three views for the external dimensions |
Performance | |
Cooling method | Water cooling |
Temperature range | 10°~ 80℃ |
Humidity range | 20%-90%RH |
Temperature /humidity fluctuation | ±2℃ / ±2.0%RH |
Temperature control accuracy | +/- 0.5C |
Humidity control accuracy | +/- 3% |
Temperature uniformity | ≤2℃ |
Heating time | From 10°C to 80°C, full-scale non-linearity averages about 2K/minute without load |
Cooling time | From 80°C to 10°C, full scale non-linearity averages about 2K/minute without load |
Temperature rise and fall overshoot | ≤±1℃ |
Schematic diagram of temperature and humidity | PS: Standard humidity 20%~95%HR |
Structure and material | |
Outer box material | Adopt advanced cold and hot steel plate non-static nano-baking paint |
Inner box material | SUS304 stainless steel plate |
Thermal insulation materials | High temperature and fire-resistant rigid polyurethane foam |
Door frame sealing strip | Silicone rubber sealing strip |
Chamber door | Double-leaf doors open outside, the door frame and the edge of the door panel are equipped with electric heating devices and overflow ditch |
Electric heating glass observation window | Quantity: 2 Location: On the door of the test room (or the place designated by the customer) Form: 3-layer vacuum strengthened glass with built-in anti-fogging heating element |
Lighting | High and low temperature resistant explosion-proof energy-saving lamp |
Pressure balance port | All aluminum alloy with anti-sweat line 4 sets of self-resetting pressure windows |
Weight bearing | Laboratory load: 500KG |
Sample hole |
A hole with a diameter of φ100mm on the left side chamber wall and equipped with a rubber isolation plug and a rubber cover at the same time.
|
Non-slip floor |
The floor adopts a 4.0mm stainless steel non-slip design to prevent personnel from being injured during internal operations.
|
Drainage | The floor is designed with a drainage tank, and the test chamber has no water inside after the end of high temperature and humidity test |
Foot cup |
The foot cup of the electric box adopts silica gel pad to absorb shock and protect the compressor and copper pipe welding
|
Noise of the whole machine | ≦80dB |
Air conditioning system | |
Constant temperature method | Adopt cold balance method |
Air cooling method | Cascade compressor refrigeration |
Circulating motor | Taiwan Tatung Low Voltage Induction Motor |
Sensor | With temperature and humidity measurement sensor and controller PT100 platinum resistance sensor |
Wind wheel | Multi-wing centrifugal circulating fan, high and low temperature resistant aluminum alloy blade |
Refrigerating system | |
Cooling method | Original imported cascade silent type, high efficiency and energy saving compressor |
Compressor |
Original imported German Bitzer semi-hermetic compressor. 2 sets of 6HP compressors
|
Refrigerant |
Non-fluorine environmental protection HFC404A (Honeywell) and DuPont R23 refrigerant
|
Condenser |
High-efficiency shell and tube type (water cooling)
Equipped with cooling water tower (well-known brand) and pipeline
|
Evaporator |
High-efficiency multi-section fin evaporator with hydrophilic membrane (thickened fin)
|
Oil separator |
Emerson AW
|
Expansion valve |
Danfoss Thermal Expansion Valve
|
Solenoid valve |
Japan Saginomiya and Danfoss
|
Other accessories |
All high-quality products of the first international brand (pictured on the right: drying filter)
|
Dehumidification |
Freezing and dehumidifying by the refrigeration system (the air in the box passes through the evaporator below the dew point temperature, and water is precipitated). *Choose evaporator fins with hydrophilic membrane treatment, better dehumidification performance, because the water tension of the hydrophilic membrane aluminum fins is small, the water droplets from air condensation are easy to slip off, and it is not easy to produce obstructive water bridges in the fin gap. Thereby greatly improving the dehumidification efficiency!
|
Heating and humidification system | |
Heating method | Electric heating |
Steam supply method | Open direct injection, the inside of the generator is directly connected to the test chamber, keeping the internal pressure close to zero |
Heating tube |
Stainless steel finned nickel-chromium alloy electric heating tube, heating tube anti-MC adhesion design, heater connection, heat-resistant wire is used, the heater is placed in the circulating air duct on the top of the box, and fire-resistant and heat-insulating materials are added around it
|
Humidification tube |
A) The humidification cylinder (boiler method) is used for humidification, which is faster than the traditional surface humidification (water pan type) and has higher control accuracy. In the box It will not produce impurity pollution such as scale, has good low-humidity performance, and is easy to clean. B) The humidification tube adopts all stainless-steel seamless casing, the insulation resistance is greater than 50MΩ, and has a dry-burn prevention controller C) The humidification cylinder is made of stainless steel and has a water level observation window. D) Low temperature with dry air
|
Humidification boiler | Installed inside the machine room |
Humidification water treatment | Equipped with a dedicated water softening device, which can effectively remove impurities in the water (1 set of pure water recovery system device, with activated carbon filter to filter water impurities). |
The main components of the control circuit |
The main components of the control circuit are all high-quality brands
|
Details