Specifications
Brand Name :
Sinuo
Model Number :
SNE6884A
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Delivery Time :
30 days
Supply Ability :
20 sets/month
Packaging Details :
Carton Box
Price :
Customized
Applied Standard :
ISO 6469, etc
Display Method :
19-inch true color screen
AC Withstand Voltage Range :
100-5000V
AC Withstand Output Load :
200VA (5000V/40mA)
DC Resistance Measuring Range :
5mΩ-200mΩ/2K-200KΩ
DC Temperature Measurement Range :
-10.0℃~+60.0℃
Insulation Resistance Output Voltage Range :
DC: 200-1000V
Insulation Resistance Measurement Range :
1.0-3000MΩ
Description

ISO 6469 Dedicated Safety Analyzer For Electric Vehicle Electronics

Complied Standards & Clauses


ISO 6469-1:2019 Electrically propelled road vehicles — Safety specifications — Part 1: Rechargeable energy storage system (RESS)

IEC 62196:2020 Plugs, socket-outlets, vehicle connectors and vehicle inlets-Conductive charging of electric vehicles

...

Equipment Overview


1. Test items: AC withstand voltage, DC withstand voltage, insulation resistance, potential equalization.

2. High precision: the basic accuracy of safety regulations is 1%.

3. Withstand voltage with arc detection, and increase the starting voltage setting; DC withstand voltage and insulation increase the charging lower limit current, and slowly increase the upper limit function.

4. Perfect protection function: DC high voltage rapid discharge device during DC withstand voltage test, to avoid residual voltage on the tested object, which may cause electric shock hazard; prevent high voltage electric shock circuit, detect loop at any time, prevent electric shock injury, and ensure personnel safety.

5. The intelligent detection function is turned on to automatically confirm the normal output of the instrument to ensure the reliability of the test.

6. The USB interface can quickly copy the set parameters, output the test results, and upgrade the program online.

7. Support bar code scanning interface, can realize fast group selection, data storage and other functions.

Function and Configuration


Standards applied ISO 6469, IEC 62196, etc
Model SNE6884A
Test Function description Ac voltage withstand, DC voltage withstand, insulation resistance, potential balance
The working conditions Working power supply AC220V±10%,50/60Hz±5%
The environment temperature 0-40℃
Environmental humidity 20-80%RH
Display mode 10.2 "full color touch screen
Over current protection Fuse, software protection
Alarm way Sound and light alarm: buzzer, indicator light
The standard Configuration Remote control interface Start, stop
Switching quantity output interface Passed, failed, testing
Communication function RS232
Alarm light interface Tri-color alarm light
The USB interface Storage test data, USB disk upgrade function
Bar code scanning interface Can be connected to the scanner gun

Technical Parameters


Insulation Resistance Test Rated output 3000V/10GΩ
Output voltage ripple Resistive load, 3000V/2mA, <1%
Output voltage setting range DC:100-3000V adjustable
Output voltage resolution/accuracy 1V ± (1% setting value+2V)
Insulation resistance setting range

Upper limit: 0.000-9.999-99.99-999.9-10000MΩ

0=closed

Lower limit: 0.1000-9.999-99.99-999.9-10000MΩ (50GΩ optional)

Insulation resistance measurement range/resolution

0.100-0.499KV: 0.100-9.999-99.99-999.9MΩ-2.000GΩ

0.500-1.000KV: 0.200-9.999-99.99-999.9MΩ-1.000GΩ-10.00GΩ

0.001 MΩ/0.01 MΩ/0.1 MΩ/1 MΩ/10MΩ

Resistance compensation >30MΩ,automatic/manual
Insulation resistance measurement accuracy

0.100-0.499KV: 0.100MΩ-9.999 MΩ, 10.00 MΩ-99.99 MΩ, 100.0 MΩ-999.9 MΩ, 1.000GΩ-2.000GΩ: ± (5% reading value+2 words)

0.500-3.000KV: 0.200MΩ-9.999 MΩ, 10.00 MΩ-99.99 MΩ, 100.0 MΩ-999.9 MΩ, ± (2% reading value+2 words)

1.000GΩ-10.00GΩ, ± (5% reading value+2 words)

Charging lower limit current 0~3.500uA, automatic/manual
Slow rise/slow fall time setting 0.1-999.9s / 0.0-999.9s
Delay/test time setting range 0.3-999.9s / 0.0 (0.0= Continuous output), 0.1-999.9s
Test time resolution/accuracy 0.1s / ± (0.1% setting value+0.05s)
AC Withstand Voltage Test Withstand voltage test type Cold state withstands voltage test
Rated output load 200VA (5000V/40mA)
Output voltage waveform, adjustment rate Sine wave, <1% (no load to full load)
Output voltage setting range AC: 100-5000V
Output voltage resolution/accuracy 1V / ± (1%× setting value +2V)
Output frequency 50Hz or 60Hz / ±0.1% × setting value
Current setting range/current zero

Upper limit: 0.000-3.999-40.00mA

Lower limit: 0.000-3.999-40.00mA

Automatic or Manual

Current measurement range/resolution

0.002-3.999-40.00mA

0.001mA/0.01mA

Current measurement accuracy ± (1% reading value +2 words)
Rise time/slow down time 0.0-999.9s
Test time setting range 0.0 (0.0= Continuous output), 0.1-999.9s
Test time resolution/accuracy 0.1s / ± (0.1% setting value +0.05s)
Starting voltage setting (0%~50%)× output voltage setting value
Arc detection Level 1-9, No.9 is the most sensitive level, 0 = closed
DC Withstand Voltage Test Withstand voltage test type Cold state withstands voltage test
Rated output load 60VA (DC: 6000V/10mA)
Output voltage ripple Resistive load (6000V/1mA) <1%
Output voltage setting range DC: 100-6000V
Output voltage resolution/accuracy 1V / ± (1% setting value +2V)
Current setting range

Upper limit: 0.000-0.399-3.999-10.00mA

Lower limit: 0.000-0.399-3.999-10.00mA

0= close

Current measurement range/current zero

0.000-0.399-3.999-10.00mA / 0.000-2.000mA

Automatic or Manual

Current measurement resolution/accuracy

0.001mA/0.04mA

± (1% reading value+2 words)

Rise time/slow down time 0.1-999.9s / 0.0-999.9s
Test time setting range 0.0 (0.0=Continuous output), 0.1-999.9s
Test time resolution/accuracy 0.1s / ± (0.1% setting value+0.05s)
Starting voltage setting (0%~50%)×output voltage setting value
Slowly rising upper limit current 0.005-9.999-10.00mA
Charging lower limit current 0.0-350.0uA DC, automatic or Manual
Discharge time ≤20mS
Arc detection Level 1-9, No.9 is the most sensitive level, 0 = closed
Potential Equalization Test Test method Four-wire system
Output voltage setting range/resolution DC: 2.0-32.0A / 0.1A
Output current accuracy ± (1% setting value +0.20A)
Resistance setting range

Upper limit: 0-600mΩ

Lower limit: 0-600mΩ

0= close

Resistance measurement range

3.00A≤|≤10.00A, 0-600mΩ;

10.00A<|≤20.00A, 0-300mΩ;

20.00A<|≤30.00A, 0-200mΩ

Resistance to zero 0-100mΩ
Resistance measurement resolution/accuracy 1mΩ / ± (1.5% reading value+3mΩ)
Test time setting range 0.0 (0.0=Continuous output), 0.1-999.9s
Test time resolution/accuracy 0.1s / ± (0.1% setting value+0.05s)

Special Test Accessories


Dedicated Electrical Safety Testing Equipment ISO 6469 For Electric Vehicle Electronics

Dedicated Electrical Safety Testing Equipment ISO 6469 For Electric Vehicle Electronics

Send your message to this supplier
Send Now

Dedicated Electrical Safety Testing Equipment ISO 6469 For Electric Vehicle Electronics

Ask Latest Price
Brand Name :
Sinuo
Model Number :
SNE6884A
Certification :
Calibration Certificate (Cost Additional)
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T
Contact Supplier
Dedicated Electrical Safety Testing Equipment ISO 6469 For Electric Vehicle Electronics

Sinuo Testing Equipment Co. , Limited

Verified Supplier
4 Years
guangdong, guangzhou
Since 2019
Business Type :
Manufacturer
Employee Number :
<100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement