1200L Programmable Constant Temperature And Humidity Test Chamber
Complied Standards & Clauses
IEC60068-2-1:2007 Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT
IEC60068-2-2:2007 Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT
IEC60068-2-30:2005 Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT
IEC60068-2-78:2012 Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT
Technical Parameters
No. | Project | Content |
A | Product number | SN881-1200L |
B | Product brand | SINUO |
C | Studio size | D1450 x W1250 X H2050 (without motor) mm |
Working Area Dimensions | Cabinet part: about 1000 D × 1000W × 1200H mm | |
D | Temperature range | -55℃~+100℃(range adjustable) |
Humidity range | 25%-98% RH (refer to the temperature and humidity controllable range chart, no moisture source or heat load)![]() | |
Temperature uniformity | ≤±2.0℃ (stable state) | |
Heating rate | 1.0℃/min (no load) | |
Cooling rate | 3.0℃/min (no load) | |
Temperature fluctuation | ≤±0.5℃ (stable state) | |
Temperature deviation | ≤±2.0℃ | |
Humidity deviation | ≤±3.0%RH | |
Load | 1000 w at +20°C; 800 w at 0°C; 500 w at -20°C; 300 w at -40°C. | |
E | Motor noise | ≤85dB |
Weight | About 780kg | |
F | Applied standards | GB/T 2423.1-2008 Test A: Low temperature test method GB/T 2423.2-2008 Test B: High temperature test method GB/T 2423.3-2006 Test Ca: Constant Damp Heat Test GB/T 2423.4-2008 Test Db: Alternating Damp Heat Test GJB 150.3A-2009 High temperature test GJB 150.4A-2009 Low temperature test GJB 150.9A-2009 Damp heat test GBT 5170.8-2016 Inspection of Environmental Test Equipment for Electrical and Electronic Products GJB150A-2009 Laboratory Environmental Test Methods for Military Equipment |
G | Note | The above performance indicators are the values measured at room temperature +25°C without sample. |
Equipment Overview
This test chamber simulates the temperature and humidity changeable environment for the products or materials. It is widely used in the adaptability test of electrical, electronics, instrument and meter and other product parts under high and low temperature and humid environment during storage, transportation and usage, to determine the temperature adaptability of the above products or materials to high and low temperature and humid environment, especially for product electrification changes in performance and mechanical properties.
Material | Inner box material | Cold-rolled steel plate, pickling and phosphating high-grade powder paint |
Outer box material | SUS304# stainless steel plate | |
Insulation material | Rigid polyurethane foam + ultra-fine glass fiber | |
Structure | Air duct parts | Centrifugal fan; the air outlet can adjust the air volume, height and return air volume |
Door | (Double) Open hinged door, with handle-type non-reaction handle, equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device, door size: (approx.) 1.0*1.2M | |
Test window | There is a conductive film explosion-proof tempered glass observation window on the door (with anti-condensation function) 500W×600H (mm) | |
Fan | Long axis centrifugal fan | |
Sample holder | Two built-in stainless steel adjustable movable trays | |
Impeller | Imported stainless steel impeller from Taiwan | |
Heater | Nickel-chromium alloy electric heater | |
Refrigeration Compressors | Imported Tecumseh compressor | |
Evaporator | Finned evaporator | |
Cooling method | Mechanical compressor cascade | |
Cooling method | Air cooling | |
Temperature control instrument | 7-inch intelligent LCD touch programmable controller | |
Lead hole | φ50mm 2 with special foam rubber stopper (located on the left side of the box) | |
Sample holder | 2 stainless steel sample racks, height adjustable. |
Heating, humidifying and cooling systems and how they work
Project | Principle description | |
Heating system | Stainless steel tube sleeve type anti-dry heating tube with built-in nickel-chromium alloy heating wire | |
U-shaped fin type stainless steel high-speed heating electric heater for heating | ||
Completely independent system, does not affect the control line | ||
Humidification system | Humidifier method | 1. External detachable boiler humidification method or built-in water tank humidification 2. Stainless steel armored humidifier 3. Humidifier control mode: non-contact equal period pulse width adjustment, SSR (solid state relay) 4. Water level control device, humidifier anti-dry burning device, sediment collection device, liquid level observation window 5. Humidifier power: 6KW |
Humidifier | 1. Automatic water supply device or push-button electric automatic water replenishment 2. RO membrane + activated carbon water supply filter, removable for cleaning 3. High and low temperature double water level electronic liquid level switch to prevent mis-operation 4. Water shortage and empty heating and over-temperature protection + ultra-low water level protection + water supply over-time protection to ensure the safe operation of the equipment | |
Refrigeration system | Cooling method | Air-cooled |
Refrigeration compressor | Adopt imported Taikang compressor, use environmentally friendly refrigerant | |
Refrigerant copper tube | Internal spiral K-TYPE refrigerant copper tube | |
Condenser | Corrugated fin type air-cooled condenser | |
Evaporator | Slope type FIN—TUBE evaporator | |
Freezing element | Original imported solenoid valve, drying filter, etc. | |
Features | The whole system pipelines are tested for leak detection by ventilating and pressurizing 22kg. | |
Heating and cooling systems are completely independent | ||
Equipped with the company's professional technical characteristics, it can prevent the high temperature and high-pressure airflow from returning to the cooling machine and damage the system. | ||
All refrigeration system action programs are completely controlled by microcomputer controller |
Name | Brand | Remark |
Compressor | Imported Tecumseh compressor | ![]() |
Pressure relay | Denmark DANFOSS or Emerson | ![]() |
Evaporating pressure regulating valve | Denmark DANFOSS | ![]() |
![]() | Denmark DANFOSS or Emerson | ![]() |
Throttling device | Capillary or Expansion Valve | ![]() |
The electromagnetic valve | Sagittarius in Japan or CASTEL in Italy or Emerson in the United States | ![]() |
Adjustment System
Project | Illustrate |
Adjustment method | Forced circulation ventilation, balanced temperature regulation. The control system controls the output of the heater according to the temperature point set by the system through the result of PID automatic calculation output, and finally achieves a dynamic balance. |
Circulation device | The built-in air-conditioning room, circulating air duct and long axial flow fan improve the air flow and heating capacity by improving the agitation airflow of the air, and greatly improve the temperature uniformity of the test chamber. |
Control System
Project | illustrate |
Controller | 7-inch PLC LCD touch programmable controller |
Touch high-definition screen | The fixed conditions and program conditions can be set arbitrarily, the Chinese screen can be set, and the curing test name and serial number can be set. |
Settable time range | 0—999H59min. |
Programmable mode
| At the same time, 120 groups of programs with different conditions can be set. In any group of programs, the work can be divided into 1200 segments, and the number of segments can be arbitrarily intercepted to execute the cycle, or the periodic cycle of any segment or group can be performed. |
In each group of programs, up to 1200 different temperature and time sections can be set (each section can be set up to 999h59min). 120 groups of programs can be connected in series at will, and the maximum number of sections can be cycled up to 999 times. | |
Safety | With a power-off memory device, the remaining programs can continue to be executed when the power is restored, and the machine can be reserved to execute the start-up and machine running time. |
Control | Rising and cooling can be used for slope control and curve control, and has the function of self-correcting temperature and humidity reference points. It has the function of PID automatic calculation, which can reduce the convenience brought by manual setting. |
Communication function | U disk interface, RS-232 interface, mis operation hardware lock, random computer communication software |
Set up | Touch setting, direct display of position, all conditions are completely automatically locked by microcomputer |
Call the police | If there is an error in the setting or operation, a warning signal will be provided |
Output | The controller has a recording signal port output, which can be connected to a temperature and humidity recorder and output a recording curve |
Interface | With standard RS-232 communication interface, long transmission distance, can be connected to PC for control and recording. |
Safety Protection Device
Cooling System | Compressor overheating protection Compressor overcurrent protection Compressor high and low pressure protection Compressor oil pressure protection Liquid temperature over-temperature protection Ultra-high pressure relief protection Air-cooled: the condensing fan is overheated |
Test box | Adjustable over temperature protection Air conditioning channel extreme over temperature protection Fan motor overheating protection |
Other | Total power phase sequence and phase loss protection (applicable to three-phase power supply) Overload and short circuit protection Refrigeration system failure alarm protection caused by multiple openings of the box |
Other configuration | |
Power cable | AC380V power supply: 1 five-core (three-phase four-wire + protective ground wire) cable (about 4 meters long) |
Main power switch | Chint Circuit Breaker |
Transportation | The test box is combined and transported separately |
Size | Maximum Shipping Dimensions (without packaging): "See Dimensions" |
weight | Maximum shipping weight (without packaging): "See Weight" |
Conditions of Use | The following conditions are guaranteed by the user |
Installation site | 1. The ground is flat and well ventilated 2. No strong vibration around the device 3. There is no strong electromagnetic field around the device 4. There is no flammable, explosive, corrosive substances and dust around the equipment 5. Appropriate space for use and maintenance should be reserved around the equipment, as shown in the following figure:
A: ≥40cm
B: ≥150cm
C: ≥100cm
D: ≥60cm
E: ≥40cm |
Environmental conditions | 1. Temperature: 5℃~35℃ 2. Relative humidity: ≤85% 3. Air pressure: 86kPa~106kPa |
Power supply conditions | AC380V power supply requirements: 1. Three-phase four-wire + protective ground wire 2. Voltage range: AC (380±38) V 3. Frequency fluctuation range: (50±0.5) Hz 4. The grounding resistance of the protective ground wire is less than 4Ω 5. The user is required to configure an air or power switch of the corresponding capacity for the equipment at the installation site, and this switch must be used independently for the equipment |
Power supply | Imax≤32A Pmax≤15KW |
Maximum current | Opening the door of the test box during the test will cause the temperature and humidity in the box to fluctuate; if the door is opened multiple times or for a long time or the test sample emits moisture during the test, it may cause the heat exchanger of the refrigeration system to freeze instead of working properly. |
Configuration
No. | Name | Model | Remark |
1 | Equipment box | Inner SUS 304 stainless steel | Feng Qianyuan |
2 | sensor | Armoured, PT100, Class A | Beijing "Sai Yiling" |
3 | AC contactor | Optional | Schneider |
4 | thermal relay | Optional | Schneider |
5 | Over temperature protection control instrument | WMK-102L(0_399) | Domestic high quality |
6 | Intermediate relay | Optional | Schneider |
7 | Circulation fan | 90W/220V | Joint venture "Zibang" |
8 | Programmable Controllers | TH2200-A | Songhua |
9 | temperature module | Songhua | |
10 | Touch screen (color screen) | Songhua | |
11 | Leakage switch | 380V63A | Chint |
12 | control transformer | BK-300 | Chint |
13 | breaker | 3P60A | Schneider |
14 | solid state relay | 40A | Taiwan "Yang Ming" |
15 | heater | Nichrome wire | Domestic high quality |
16 | compressor | Optional | German "Bitzer" |
17 | Evaporator | custom made | Taiwan Zhongli |
18 | The refrigerant | R404A/R23 | DuPont USA |
19 | Frozen oil | RL32H | British ice bear |
20 | oil separator | Large system supporting 55824/55855 | Emerson (formerly ALCO, USA) |
21 | Gas-liquid separator | Large system supporting 3/8″, 1/2″ | Fuzhou, Taiwan |
23 | filter drier | DCL032/053/083/085 | Danfoss Denmark or Sporland USA |
24 | The electromagnetic valve | 3/8 or 5/8 | Sagittarius or Kasto in Japan |
25 | Evaporator | Custom | Joint venture |
26 | Copper miscellaneous parts | Optional | Taiwan Xiongde |
Product features and advantages
PWM Valve Normal Valve