Walk-in Constant Temperature and Humidity Environmental Test Chamber
Complied Standards & Clauses
IEC 60068-2-1 Test A: Low-temperature test method.
IEC 60068-2-2 Test B: High-temperature test method.
IEC 60068-2-3 Test Ca: Constant damp heat test method.
IEC 60068-2-30 test Db: alternating damp heat test method.
Equipment Overview
This walk-in chamber provides precise, programmable control of both temperature and humidity, making it ideal for environmental simulation testing of large components, EV systems, aerospace parts, electronics, and industrial equipment.Designed for high-precision environmental testing, this spacious 12m³ walk-in chamber simulates extreme temperature and humidity conditions to ensure product durability and reliability. Ideal for EV components, electronics, aerospace, and industrial materials testing.
Technical Parameters
Volume and dimensions | |
Effective volume | 12m³ |
Inner chamber size | 3000 mm*2000 mm*2000mm(W*H*D) |
Outer chamber size | Approximately 3700 mm*2200 mm*2300 mm(W*H*D) Warm reminder: Please refer to the three views of the final design for external dimensions. |
Container size | The inner dimensions of the 40HQ container are 12.032m (L)*2.352m (W)*2.69m(H) The door is 2.55M high (it will be extra wide after being packed with wooden boxes) |
Performance | |
Cooling method | Water cooling |
Temperature range | -40°~ 150℃ |
Humidity range | 20%RH~95%RH |
Temperature/humidity fluctuation | ±2℃/±2.0%RH |
Temperature analysis accuracy | 0.01℃ |
Humidity analysis accuracy | 0.01RH |
Temperature uniformity | ≤2℃ |
Humidity uniformity | < 75%RH:±3%RH >75%RH±5%RH |
Heating rate | ≦3.0℃/min (non-linear, no load) |
Cooling rate | Average 1.0℃/min (non-linear, no load) |
Load condition | No load |
Details