Specifications
Brand Name :
CODT
Model Number :
EX-QM01
Certification :
ATEX, IECEx,ETL,API,ABS
Place of Origin :
CHINA
MOQ :
negotiable
Price :
negotiable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
500 pcs per day
Delivery Time :
5-20days
Packaging Details :
carton box standard, check the specification
Material :
Copper-free aluminum
Item type :
Explosion- Cable Gland
Color temperature(cct) :
pure white, cool white ,warm white
Ip rating :
66
Working temperature :
-50°C to 80°C in dynamic state
Size :
PG cable gland
Description

Free Sample M12 to M75 Hazardous Area Cable Glands Explosion Proof Flameproof Non-armoured Zones 1 2 21 and 22

  • EX-QM01-A1

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable.

Ex e, structure.

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEX

Ex eb ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperature:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length GL(mm) Nominal Protrusion
Length L(mm)
Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 NPT3/8 9.5 12 16 30 27(29)
20 M20*1.5 NPT1/2 9.5 16.5 16 30 27(29)
25 M25*1.5 NPT3/4 14 20 16 38 34(37)
32 M32*1.5 NPT1 18 26 18 44 40(44)
40 M40*1.5 NPT1 1/4 24 32.5 18 46 50(55)
50 M50*1.5 NPT1 1/2 30 41 20 50 60(67)
63 M63*1.5 NPT2 40 52 21 64 68(73)
75 M75*1.5 NPT2 1/2 50 65 22 70 86(89)
90 M90*1.5 NPT3 62 77 22 80 102(105)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM03-C1K

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb

Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68

Marking IECEx

Ex eb ⅡC Gb

Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter Minimum Thread Length GL(mm) Nominal Protrusion
Length L(mm)
Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Max
16 M16*1.5 NPT3/8 9.5 12 / 16 65 24(29)
20 M20*1.5 NPT1/2 9.5 16.5 / 16 67 30(34)
25 M25*1.5 NPT3/4 14 20 / 16 71 36(40)
32 M32*1.5 NPT1 18 26 / 18 76 45(51)
40 M40*1.5 NPT1 1/4 24 32.5 / 18 76 55(61)
50 M50*1.5 NPT1 1/2 30 41 / 20 91 68(74)
63 M63*1.5 NPT2 40 52 / 21 98 86(95)
75 M75*1.5 NPT2 1/2 50 65 / 22 102 95(109)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM04-B1K

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Dual seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking IECEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter Minimum Thread Length GL(mm) Nominal Protrusion
Length L(mm)
Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Min Max
16 M16*1.5 NPT3/8 9.5 12 6.5 10.5 16 65 24(29)
20 M20*1.5 NPT1/2 9.5 16.5 10 14.5 16 67 30(34)
25 M25*1.5 NPT3/4 14 20 12.5 19.5 16 71 36(40)
32 M32*1.5 NPT1 18 26 19 25.5 18 76 45(51)
40 M40*1.5 NPT1 1/4 24 32.5 25 31 18 76 55(61)
50 M50*1.5 NPT1 1/2 30 41 31.5 43 20 91 68(74)
63 M63*1.5 NPT2 40 52 42.5 50 21 98 86(95)
75 M75*1.5 NPT2 1/2 50 65 54.5 65 22 102 95(109)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM05-C1K

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking IECEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter Minimum Thread Length L1(mm) Total Length l(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Max
16 M16*1.5 NPT3/8 7 16 8 15 85 24(27)
20 M20*1.5 NPT1/2 7 16 10.5 15 87 24(27)
25 M25*1.5 NPT3/4 14 20 15 15 88 30(33)
32 M32*1.5 NPT1 18 25 20 17 96 36(39)
40 M40*1.5 NPT1 1/4 24 33 27 19 105 45(50)
50 M50*1.5 NPT1 1/2 31 40 31 19 108 55(60)
63 M63*1.5 NPT2 41 50 41 20 118 68(73)
75 M75*1.5 NPT2 1/2 52 63 55 21 124 86(89)
90 M90*1.5 NPT3 65 76 65 24 128 96(99)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM06-B1K

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Dual seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter Minimum Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Min Max
16 M16*1.5 NPT3/8 7 16 5 8 15 85 24(27)
20 M20*1.5 NPT1/2 7 16 5 10.5 15 87 24(27)
25 M25*1.5 NPT3/4 14 20 8 15 15 88 30(33)
32 M32*1.5 NPT1 18 25 11 20 17 96 36(39)
40 M40*1.5 NPT1 1/4 24 33 14 27 19 105 45(50)
50 M50*1.5 NPT1 1/2 31 40 20 31 19 108 55(60)
63 M63*1.5 NPT2 41 50 30 41 20 118 68(73)
75 M75*1.5 NPT2 1/2 52 63 42 55 21 124 86(89)
90 M90*1.5 NPT3 65 76 52 65 24 128 96(99)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM10-B1

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 NPT3/8 4 7 16 62 27(29)
20 M20*1.5 NPT1/2 5 8 16 62 27(29)
25 M25*1.5 NPT3/4 8 12 16 62 30(33)
32 M32*1.5 NPT1 12 16 18 67 38(42)
40 M40*1.5 NPT1 1/4 16 24 20 77 45(50)
50 M50*1.5 NPT1 1/2 18 28 20 79 55(60)
63 M63*1.5 NPT2 25.5 38 20 81 68(73)
75 M75*1.5 NPT2 1/2 29 46 20 100 85(89)
90 M90*1.5 NPT3 41 60 21 100 98(102)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM10-B1

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Nominal Protrusion Length(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 / 5 8 15 30 24(27)
20 M20*1.5 NPT1/2 7.5 11.5 15 30 24(27)
25 M25*1.5 NPT3/4 11 14.5 15 30 30(33)
32 M32*1.5 NPT1 14 20 20 32 36(39)
40 M40*1.5 NPT1 1/4 19 20 20 32 45(50)
50 M50*1.5 NPT1 1/2 25 32 20 36 55(60)
63 M63*1.5 NPT2 31.5 42.5 20 37 68(73)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM13-B1T

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Nominal Protrusion Length(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 / 5 8 15 40 24(27)
20 M20*1.5 NPT1/2 7.5 11.5 15 40 24(27)
25 M25*1.5 NPT3/4 11 14.5 15 40 30(33)
32 M32*1.5 NPT1 14 20 20 44 36(39)
40 M40*1.5 NPT1 1/4 19 20 20 48 45(50)
50 M50*1.5 NPT1 1/2 25 32 20 49 55(60)
63 M63*1.5 NPT2 31.5 43.5 20 63 68(73)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM18-C1

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Nominal Protrusion Length(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 / 5 8 15 57 24(27)
20 M20*1.5 NPT1/2 5 8 15 57 24(27)
20 M20*1.5 NPT1/2 7.5 11.5 15 57 24(27)
25 M25*1.5 NPT3/4 11 14.5 15 57 30(33)
32 M32*1.5 NPT1 14 20 20 59 36(39)
40 M40*1.5 NPT1 1/4 19 26 20 60 45(50)
50 M50*1.5 NPT1 1/2 25 32 20 62 55(60)
63 M63*1.5 NPT2 31.5 43.5 20 73 68(73)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM21-C1K

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter Minimun Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Max
16 M16*1.5 NPT3/8 9.5 12 7 16 66 27(29)
20 M20*1.5 NPT1/2 9.5 16.5 12 16 66 27(29)
25 M25*1.5 NPT3/4 14 20 17 16 68 34(37)
32 M32*1.5 NPT1 18 26 23 18 77 40(44)
40 M40*1.5 NPT1 1/4 24 32.5 30 18 81 50(55)
50 M50*1.5 NPT1 1/2 30 41 37 20 88 60(67)
63 M63*1.5 NPT2 40 52 52 21 96 68(73)
75 M75*1.5 NPT2 1/2 50 65 62 22 114 86(89)
90 M90*1.5 NPT3 62 77 66 22 119 102(105)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • EX-QM22-B1K

IP66 Flame Proof Cable Glands

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Dual seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

IP66 Flame Proof Cable Glands

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter Minimun Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Min Max
16 M16*1.5 NPT3/8 9.5 12 5 8 15 66 27(29)
20 M20*1.5 NPT1/2 9.5 16.5 8 10.5 15 66 27(29)
25 M25*1.5 NPT3/4 14 20 10 15 15 68 34(37)
32 M32*1.5 NPT1 18 26 15 19.5 19 77 40(44)
40 M40*1.5 NPT1 1/4 24 32.5 19 26 19 81 50(55)
50 M50*1.5 NPT1 1/2 30 41 26 32 19 88 60(67)
63 M63*1.5 NPT2 40 52 31.5 40 19 96 68(73)
75 M75*1.5 NPT2 1/2 50 65 38 50 19 114 86(89)
90 M90*1.5 NPT3 62 77 54.5 62 19 119 102(105)
  • SCHEMATIC DIAGRAM

IP66 Flame Proof Cable Glands

  • ORDERING GUIDE

IP66 Flame Proof Cable Glands

  • QA:

Q1. How do you ship the goods and how long does it take to arrive?

A: Ship by DHL, UPS, FedEx or TNT. It takes 3-5 days to arrive. Airline and sea shipping also optional.

Q2. Can I have a sample order for led light?

A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

Send your message to this supplier
Send Now

IP66 Flame Proof Cable Glands

Ask Latest Price
Brand Name :
CODT
Model Number :
EX-QM01
Certification :
ATEX, IECEx,ETL,API,ABS
Place of Origin :
CHINA
MOQ :
negotiable
Price :
negotiable
Contact Supplier
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands
IP66 Flame Proof Cable Glands

Shenzhen CODT technology co.,Ltd

Active Member
3 Years
shenzhen
Since 2013
Business Type :
Manufacturer
Total Annual :
5000000-1000000
Employee Number :
180~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement