Explosion PD61 Series
Copper free aluminum, plastic-sprayed surface.
Ex d type flameproof enclosure.
Can be used as terminal box, distribution box and control box.
Degree of protection: IP66.
Marking ATEX: Ⅱ 2 G Ex db ⅡB+H₂ T□ Gb 1)
Ⅱ 2 D Ex tb ⅢC T□ Db IP66
Note: See the technical data of EX-PD61-JX-IIB, 1) EX-PD61-ZM, EX-PD61-DL, EX-PD61-ZC-A, EX-PD61-LK, EX-PD61-QD
Marking IECEx: Ex db ⅡB+H₂ T□ Gb 1)
Ex tb ⅢC T□ Db IP66
Note: See the technical data of EX-PD61-JX-IIB, 1) EX-PD61-ZM, EX-PD61-DL, EX-PD61-ZC-A, EX-PD61-LK, EX-PD61-QD
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards: EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31
Rated Voltage: Max.100V AC, 50/60Hz
Rated Current: Max.1,200A
Ambient Temperature:-60℃ to + 60℃
Cable Entry :Standard M□×1.5 Plug, See the Specification Table
Entry Direction :Bottom
Cable Entry Device :Optional
Type of Flameproof Joint :Cylindrical Joint, Threaded Joint, PlaneJoint
Installation Type :Wall Mounting(Standard); Bracket Mounting(Optional)
Built-in Components:Main switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB)(Noted: earth leakage protection on
request)
Branch switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB) (Noted: earth leakage protection on request)
Terminal Indicator light EX-D: Red, green, yellow, blue
Button EX-A: Red, green, yellow
AC contactor
Thermal overload relay
PLC programmer
Soft starter
Control switch EX-K
Ammeter/Voltmeter
Code | Max Dissipated Power(W) | Max Rated Current | External Dimension | Internal Dimension | Mounting Dimension | ||||||||
T4/T130℃ | T5/T95℃ | T6/T80℃ | A | B | C | a | b | c | d | e | f | ||
EX-PD61-A | 200 | 120 | 80 | 63A | 250 | 200 | 170 | 192 | 142 | 131 | 180 | 130 | 10 |
EX-PD61-B | 200 | 120 | 80 | 63A | 300 | 200 | 170 | 242 | 142 | 131 | 230 | 130 | 10 |
EX-PD61-C | 240 | 140 | 100 | 100A | 350 | 200 | 170 | 292 | 142 | 131 | 280 | 130 | 10 |
EX-PD61-D | 350 | 200 | 130 | 200A | 350 | 300 | 270 | 290 | 240 | 229 | 280 | 230 | 12 |
EX-PD61-E | 500 | 280 | 160 | 320A | 450 | 350 | 280 | 378 | 278 | 233 | 365 | 265 | 12 |
EX-PD61-F | 620 | 350 | 200 | 500A | 560 | 450 | 280 | 488 | 328 | 225 | 475 | 315 | 14 |
EX-PD61-G | 700 | 400 | 250 | 1000A | 720 | 560 | 350 | 640 | 480 | 285 | 620 | 460 | 14 |
EX-PD61-H | 800 | 500 | 350 | 1000A | 980 | 720 | 375 | 880 | 620 | 290 | 820 | 560 | 18 |
Suitable for terminal box of distribution system.
Note: 1. The EX-PD61 terminal box wiring terminals have various arrangements methods.
2. It can be customized according to customer requirements and always meets the restrictions of the certificate. The maximum number of terminals and the maximum number of holes on the side meet the requirements of power dissipation and mechanical strength of the enclosure.
3. This table is for reference only.
1). Please specify the direction and size of each cable entry.
2). Cable entry is optional, and EX-QM-B(Ex d) or EX-QM-C(Ex d) is recommended.
Cable Cross-sectional Area(mm)² | Table for Max number of fitted terminal | ||||||||
Enclosure type number(Note: The enclosure type number is correspondent to the size. For example: A stands for the enclosure of 200x250) | |||||||||
A | B | C | D | E | F | G | H | ||
2.5(a) | 20 | 28 | 36 | 72 | 100 | 140 | 270 | 264 | 396 |
4(b) | 18 | 25 | 32 | 64 | 90 | 130 | 240 | 248 | 372 |
6(c) | 15 | 21 | 28 | 56 | 80 | 100 | 210 | 200 | 300 |
10(d) | 12 | 18 | 24 | 24 | 60 | 80 | 165 | 160 | 240 |
16(e) | 9 | 15 | 20 | 20 | 25 | 70 | 135 | 136 | 204 |
35(f) | - | 5 | 5 | 10 | 15 | 24 | 64 | 90 | 135 |
70(g) | - | - | - | 5 | 10 | 18 | 25 | 72 | - |
120(h) | - | - | - | - | 5 | 5 | 12 | 42 | - |
185(i) | - | - | - | - | - | 5 | 10 | - | - |
240(j) | - | _ | - | - | - | 5 | 5 | - | - |
300(k) | - | - | - | - | - | 5 | 5 | - | - |
Terminal Arrangement (Number of terminal rows) | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 |
Suitable for control unit distribution system
Note: 1. EX-A buttons, EX-D indicators, EX-K control switches, EX-B-A ammeters and EX-A-V voltmeters, etc. are included in EX-PD61 control boxes.
2. The control box can be used for on-off operation of circuit,as well as the remote control or local control of the strat,stop,corotation and inversion of motor,When equipped with ammeter,it also can monitor the running of motor and circuit status.
3. It can be customized in accordance with customer's requirements and conforms to the usage limits of conformity certificate. The number of cover components and the max. number of holes on the side can meet the requirements of dissipated power and enclosure mechanical strength.
Suitable for power unit of distribution system
Note: 1.MCB (Miniature Circuit Breaker)or MCCB(Moulded Case Circuit Breaker),AC contactor thermal overload relay,PLC programmer,soft starter,EX-A pushbuttons.EX-D indication, EX-K control switches,EX-B-A ammeters and EX-A-V voltmeters etc.are included in the box.
2. The control box can be used for power distribution or on-off operation of the circuit, as well as the control of the start, stop, corotation and inversion of motor and provide comprehensive protection for motor. It can be set up for two-site control or multi-site control.
3. It can be customized in accordance with customer's requirements and conforms to the usage limits of conformity certificate. The number of cover components and max. number of holes on the side can meet the requirements of dissipated and encloure mechanical strength.
Copper free aluminum, plastic-sprayed surface.
Ex d type flameproof enclosure.
Degree of protection: IP66-IP67.
Marking ATEX: II2 G Ex db IIB+H2 T6/T5 Gb
II2 D Ex tb IIIC T80ºC/95ºC Db IP66
Marking IECEx:Ex db ⅡB+H₂ T6/T5 Gb
Ex tb ⅢC T80℃/T95℃ Db IP66
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards: EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31
Rated Voltage : Max.800V
Rated Current: Cable Cross Section(mm²) 2.5 4 6 10 16 35 70 240
Rated Current(A) 24 32 41 57 76 125 192 400
Ambient Temperature:-60℃ to + 60℃
Type of Flameproof Joint:Plane Joint
A,B,C,D stands for the directiond of cable entries | ||||||||||||||
Max.number of cable entry | ||||||||||||||
Enclosure type | A | B | C | D | E | F | G | |||||||
Dimension | A/B | C/D | A/B | C/D | A/B | C/D | A/B | C/D | A/B | C/D | A/B | C/D | A/B | C/D |
M20*1.5 | 5 | 8 | 5 | 10 | 5 | 12 | 16 | 20 | 22 | 30 | 24 | 40 | 45 | 65 |
M25*1.5 | 5 | 7 | 5 | 9 | 5 | 10 | 12 | 15 | 15 | 20 | 18 | 27 | 30 | 44 |
M32*1.5 | 2 | 3 | 2 | 4 | 2 | 6 | 9 | 12 | 12 | 16 | 14 | 21 | 25 | 36 |
M40*1.5 | 2 | 2 | 2 | 3 | 2 | 4 | 5 | 6 | 6 | 9 | 8 | 12 | 15 | 21 |
M50*1.5 | 1 | 2 | 1 | 3 | 1 | 3 | 4 | 5 | 5 | 7 | 5 | 9 | 12 | 12 |
M63*1.5 | 1 | 2 | 1 | 2 | 1 | 3 | 2 | 3 | 3 | 5 | 4 | 7 | 7 | 10 |
Note: 1. No cable entry for standard design. Cable entries shall be drilled by user. 2. No cable entry device. |
Cable Cross-sectional Area(mm)² | Table for Max number of fitted terminal | |||||||
Enclosure type number(Note: The enclosure type number is correspondent to the size. For example: A stands for the enclosure of 200x250) | ||||||||
A | B | C | D | E | F | G | H | |
2.5(a) | 20 | 28 | 36 | 72 | 100 | 140 | 270 | 270 |
4(b) | 18 | 25 | 32 | 64 | 90 | 130 | 240 | 240 |
6(c) | 15 | 21 | 28 | 56 | 80 | 100 | 210 | 210 |
10(d) | 12 | 18 | 24 | 24 | 60 | 80 | 165 | 165 |
16(e) | 9 | 15 | 20 | 20 | 25 | 70 | 135 | 135 |
35(f) | - | 5 | 5 | 10 | 15 | 24 | 64 | 64 |
70(g) | - | - | - | 5 | 10 | 18 | 25 | 25 |
120(h) | - | - | - | - | 5 | 5 | 12 | 12 |
185(i) | - | - | - | - | - | 5 | 10 | 10 |
240(j) | - | _ | - | - | - | 5 | 5 | 5 |
300(k) | - | - | - | - | - | 5 | 5 | 5 |
Terminal Arrangement (Number of terminal rows) | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 |
Copper free aluminum, stainless steel.
Plastic-sprayed surface.
Earth leakage protection device is optional.
Degree of protection: IP66-IP67.
Marking ATEX: Ⅱ 2 G Ex d ⅡB T6 Gb
Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66
Marking IECEx: Ex db ⅡB+H₂ T6 Gb
Ex tb ⅢC T80℃ Db IP66
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards : EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31
Rated Voltage: Max.690V AC, 50/60Hz
Rated Current: Max.100A
Branch Current: 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A
Ambient Temperature: -60℃ to + 55℃
Degree of Protection: IP66, IP67
Cable Entry: Standard M□×1.5 Plug(See the Selection Table)
Entry Direction: Bottom(in and out)
Cable Entry Device:Optional
Type of Flameproof Joint: Cylindrical Joint, Threaded Joint, Plane Joint.
Installation Type: Wall mounting(standard); Bracket mounting(optional)
Built-in Components:
Main switch: miniature circuit breaker(MCB) or molded case circuit break(Noted: earth leakage protection on request) Branch switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB) (Noted: earth leakage protection on request)
Terminal Indicator: Red, green, yellow
Code | Description | Cable entries | ||||
Main switch | Number of branch | Branch switch | Branch current | Number of indicator | ||
EX-PD61-ZM-/4□/K/□ | MCB or MCCB Current Max.100A | 4 | MCB 1P/2P | 1A 2A 4A 6A 10A 16A 20A 25A 32A On request | 3 | 1*M32*1.5+4*M25*1.5 |
EX-PD61-ZM-/6□/K/□ | 6 | 3 | 1*M40*1.5+6*M25*1.5 | |||
EX-PD61-ZM-/8□/K/□ | 8 | 3 | 1*M40*1.5+8*M25*1.5 | |||
EX-PD61-ZM-/10□/K/□ | 10 | 3 | 1*M40*1.5+10*M25*1.5 | |||
EX-PD61-ZM-/12□/K/□ | 12 | 3 | 1*M40*1.5+12*M25*1.5 | |||
EX-PD61-ZM-4/□ | _ | 4 | MCB 1P/2P | 1A 2A 4A 6A 10A 16A 20A 25A 32A On request | 3 | 1*M32*1.5+4*M25*1.5 |
EX-PD61-ZM-6/□ | 6 | 3 | 1*M40*1.5+6*M25*1.5 | |||
EX-PD61-ZM-8/□ | 8 | 3 | 1*M40*1.5+8*M25*1.5 | |||
EX-PD61-ZM-10/□ | 10 | 3 | 1*M40*1.5+10*M25*1.5 | |||
EX-PD61-ZM-12/□ | 12 | 3 | 1*M40*1.5+12*M25*1.5 |
1. Please specify the number and size of the cable inlets and the mounting surface of the housing.
2. The user provides the electrical diagram. If you need light controller, AC contactor or thermal relay control, please specify.
3. Please specify special requirements when ordering.
Dimensional drawings
EX-PD61-ZM-/4□/K/□
EX-PD61-ZM-/6□/K/□
EX-PD61-ZM-/8□/K/□
EX-PD61-ZM-/10□/K/□
EX-PD61-ZM-/12□/K/□
Copper free aluminum, stainless steel.
Plastic-sprayed surface.
Earth leakage protection device is optional.
Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb
II 2 D Ex tb ⅢC T80℃ Db IP66
Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb
Ex tb ⅢC T80℃ Db IP66
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31
Rated Voltage: Max.690V AC, 50/60Hz
Branch Current: : 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, 160A, 200A, 250A, 320A, 400A
Ambient Temperature: -60℃ to + 55℃
Degree of Protection: IP66,IP67
Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table )
Entry Direction: Bottom (in and out)
Cable Entry Device: Optional
Type of Flameproof Joint: Wall Mounting(Standard); Bracket Mounting(Optional)
Built-in Components: Main switch: miniature circuit breaker (MCB)or molded case circuit breaker(MCCB)
(Noted:earth leakage protection on request)
Branch switch: miniature circuit breaker (MCB)or molded case circuit breaker(MCCB)
(Noted:earth leakage protection on request)
Terminal
Indicator: Red, green, yellow
Code | Description | Cable entries | ||||
Main switch | Number of branch | Branch switch | Branch current | Number of indicator | ||
EX-PD61-DL-/4□/K/□ | MCB or MCCB Current Max.100A | 4 | MCB or MCCB 3P | 1A 2A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 320A 400A On request | 3 | 1*M50(M63,M75,M90)*1.5 4*M25(M32,M40,M50,M63)*1.5 |
EX-PD61-DL-/6□/K/□ | 6 | 3 | 1*M50(M63,M75,M90)*1.5 6*M25(M32,M40,M50,M63)*1.5 | |||
EX-PD61-DL-/8□/K/□ | 8 | 3 | 1*M50(M63,M75,M90)*1.5 8*M25(M32,M40,M50,M63)*1.5 | |||
EX-PD61-DL-/10□/K/□ | 10 | 3 | 1*M50(M63,M75,M90)*1.5 10*M25(M32,M40,M50,M63)*1.5 | |||
EX-PD61-DL-/12□/K/□ | 12 | 3 | 1*M50(M63,M75,M90)*1.5 12*M25(M32,M40,M50,M63)*1.5 | |||
EX-PD61-DL-4/□ | _ | 4 | MCB or MCCB 3P | 1A 2A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 160A 200A 250A 320A 400A On request | 3 | 1*M40*1.5+4*M25*1.5 |
EX-PD61-DL-6/□ | 6 | 3 | 1*M40*1.5+6*M25*1.5 | |||
EX-PD61-DL-8/□ | 8 | 3 | 1*M40*1.5+8*M25*1.5 | |||
EX-PD61-DL-10/□ | 10 | 3 | 1*M40*1.5+10*M25*1.5 | |||
EX-PD61-DL-12/□ | 12 | 3 | 1*M40*1.5+12*M25*1.5 |
Odering instruction: 1. Please specify the number and size of the cable inlets and the mounting surface of the housing.
2. The user provides the electrical diagram. If you need light controller, AC contactor or thermal relaycontrol, please specify.
3. Please specify special requirements when ordering
Copper free aluminum, stainless steel.
Plastic-sprayed surface.
Earth leakage protection device is optional.
Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb
II 2 D Ex tb ⅢC T80℃ Db IP66
Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb
Ex tb ⅢC T80℃ Db IP66
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31
Rated Voltage: Max.415V AC
Rated Current: 10A
Ambient Temperature: -60℃ to + 60℃
Degree of Protection: IP66,IP67
Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table )
Entry Direction: Bottom
Cable Entry Device: Standard M□× 1.5 Plug ( See the Selection Table )
Type of Flameproof Joint: Cylindrical Joint,Threaded Joint,Plane Joint.
Built-in Components: EX-A Pushbutton, EX-D Indicator,EX-K Control Switch, Explosion-proof Ammeter/Voltmeter
Installation Type: Wall Mounting
Indicator: Red, green, yellow
Copper free aluminum, stainless steel.
Plastic-sprayed surface.
Earth leakage protection device is optional.
Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb
II 2 D Ex tb ⅢC T80℃ Db IP66
Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb
Ex tb ⅢC T80℃ Db IP66
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31
Type of Flameproof Joint: Cylindrical Joint,Plane Joint.
EX-PD61-LK-63/□/□/□
EX-PD61-LK-160/□/□/□
EX-PD61-LK-250/□/□/□
Copper free aluminum, stainless steel.
Plastic-sprayed surface.
Earth leakage protection device is optional.
Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb
II 2 D Ex tb ⅢC T80℃ Db IP66
Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb
Ex tb ⅢC T80℃ Db IP66
Marking UL1203: Class I, Division 1, Groups C, D
Class I, Division 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31
Rated Voltage: 380/400V AC, 50/60Hz
Rated Current: 10A
Ambient Temperature: T6/T80 ℃ for Tamb: -60℃ to +50℃;
T5/T95 ℃ for Tamb: -60℃ to +60℃
Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table )
Entry Direction: Bottom(in and out)
Cable Entry Device: Optional
Type of Flameproof Joint: Cylindrical Joint,Threaded Joint,Plane Joint.
Built-in Components: Miniature circuit breaker(MCB) or moulded case circuit breaker( MCCB)
AC contactor, thermal overload relay, indicator, button
Direct Start | |||||
Model | Control motor power(kw) | Rated current of circuit breaker(A) | Adjustable range of setting current of thermalr elay(A) | Rated current of contactor(A) | Cable entry size |
EX-PD61 QD-4/16/7~10 | 4 | 16 | 7~10,le=8.5 | 9 | 2*M25*1.5 |
EX-PD61 QD-5.5/20/9~13 | 5.5 | 20 | 9~13,le=11 | 12 | 2*M25*1.5 |
EX-PD61 DQ-7.5/25/12~18 | 7.5 | 25 | 12~18,le=16 | 18 | 2*M32*1.5 |
EX-PD61 QD-11/32/16~24 | 11 | 32 | 16~24,le=23 | 25 | 2*M32*1.5 |
EX-PD61 QD-15/40/23~32 | 15 | 40 | 23~32,le=30 | 32 | 2*M32*1.5 |
EX-PD61 QD-18.5/50/30~38 | 18.5 | 50 | 30~38,le=36 | 40 | 2*M40*1.5 |
EX-PD61 QD-22/63/37~50 | 22 | 63 | 37~50,le=46 | 50 | 2*M40*1.5 |
Forward and Reverse Start | |||||
Model | Control motor power(kw) | Rated current of circuit breaker(A) | Adjustable range of setting current of thermalr elay(A) | Rated current of contactor(A) | Cable entry size |
EX-PD61 QD-4/16/7~10 N | 4 | 16 | 7~10,le=8.5 | 9 | 2*M25*1.5 |
EX-PD61 QD-5.5/20/9~13 N | 5.5 | 20 | 9~13,le=11 | 12 | 2*M25*1.5 |
EX-PD61 DQ-7.5/25/12~18 N | 7.5 | 25 | 12~18,le=16 | 18 | 2*M32*1.5 |
EX-PD61 QD-11/32/16~24 N | 11 | 32 | 16~24,le=23 | 25 | 2*M32*1.5 |
EX-PD61 QD-15/40/23~32 N | 15 | 40 | 23~32,le=30 | 32 | 2*M32*1.5 |
EX-PD61 QD-18.5/50/30~38 N | 18.5 | 50 | 30~38,le=36 | 40 | 2*M40*1.5 |
EX-PD61 QD-22/63/37~50 N | 22 | 63 | 37~50,le=46 | 50 | 2*M40*1.5 |