1.Equipment working status monitoring.
2.Water shortage alarm at the tail end: can interface with the environmental control system, issuing audible and
visual alarm signals as well as network alerts.
3.Monitoring of water volume over 20 days and 24-hour water volume monitoring.
4.Automatic flushing of water lines.
5.Automatic dosing system.
6.Drinking water upper and lower limit alerts.
7.Pulsed flushing can be controlled in 1 to 4 groups.
8.Can be integrated with the Shengxing Smart Farming Platform.
Model | SX-YS |
Control Water Line Quantity | 1-72 Lines |
Power Supply | 220V 50HZ |
Water Volume Monitoring Accuracy | 0.5L |
No. | Name | Function |
1 | Working Status | Displays the current working status and progress, shows the duration of the current flushing and the time for the next flushing. |
2 | Low Water Alarm | Displays the low water alarm status, along with the low water alarm switch and audio-visual signal switch. |
3 | Function Button | Selects the device's function |
4 | Water Consumption Data | Displays water consumption data for the last 20 days and the last 24 hours. |
5 | Time Display | Shows the current time |
No. | Name | Function |
1 | Flushing Switch | Sets whether the corresponding layer is enabled for flushing. |
2 | Status Monitoring | Monitors the flushing status and includes control buttons. |
3 | Flushing Parameters | Sets the parameters for flushing |
4 | Pulse Parameters | Pulse Parameters: Sets the parameters for air pulses |
No. | Name | Function |
1 | Pulse group settings | set the flushing group corresponding to each layer |
No. | Name | Function |
1 | dosing switch | Set whether to enable dosing for the corresponding layer |
2 | dosing status | Display the status of the dosing and control buttons |
3 | Pipeline cleaning settings | Set the time for emptying the pipeline and whether to automatically add the dosing after cleaning |
4 | dosing holding parameters | Set the holding time after adding the dosing and whether to flush after the holding period ends |
5 | dosing timing parameters | Set parameters related to the dosing timing |
Query the data record of drinking water consumption.
No. | Name | Function |
1 | Water Level Status | Displays the corresponding water level status.if low water is detected, the relevant position will flash |
2 | Low Water Alarm Text | Display the text records for the low water alarm and the deactivation of the low water alarm |
No. | Name | Function |
1 | Chicken Coop Parameters | Set the number of columns and layers in the chicken coop |
2 | Real-time Water Volume | Total water consumed |
3 | Clear Drinking Records | Reset all water volume records to zero |
4 | Drinking Volume Monitoring | Set whether to enable water volume monitoring; this function requires configuration of a pulse water meter |
5 | Flushing Water Settings | Set whether to include flushing water in the daily and hourly records |
6 | Drinking Limit Settings | Set the upper and lower limits for daily water consumption. The upper limit can be used to determine if there is a leak in the water line, while the lower limit can be used to assess if water supply is insufficient. Exceeding the upper limit will be indicated in red, while falling below the lower limit will be indicated in yellow |