Rectifier Diode Switching 600V 1A 250ns 2-Pin DO-41 RoHS Compliant
FR101~FR107 DO-41 Datasheet.pdf
Ratings at 25 C ambient temperature unless otherwise specified.Single phase half-wave 60Hz,resistive or inductive load,for capacitive load current derate by 20%.
Parameter | SYMBOLS | FR101 | FR102 |
FR103
| FR104 | FR105 | FR106 | FR107 | UNITS | |
Maximum Repetitive Peak Reverse Voltage | VRRM | 50 | 100 |
200
| 400 | 600 | 800 | 1000 | Volts | |
Maximum RMS Voltage | VRMS | 35 | 70 |
140
| 280 | 420 | 560 | 700 | Volts | |
Maximum DC Blocking Voltage | VDC | 50 | 100 |
200
| 400 | 600 | 800 | 1000 | Volts | |
Maximum Average Forward Rectifier Current at TL=100°C | IF(AV) | 1 | Amps | |||||||
Peak Forward Surge Current ,8.3msSingle Half Sine-Wave Superimposed on rated load | IFSM | 30 | Amps | |||||||
Maximum Instantaneous Forward Voltage At 1A | VF | 1.3 | Volts | |||||||
Maximum DC Reverse Current at rated DC blocking voltage | TA=25°C | IR | 10 | μA | ||||||
TA=125°C | 500 | |||||||||
Maximum Reverse Recovery Time | Trr | 150 | 250 | 500 | ns | |||||
Typical Junction Capacitance | CJ |
12
| PF |
Note: 1.Reverse recovery condition IF =0.5A,IR =1.0A,Irr=0.25A
2.Measured at 1MHz and applied reverse voltage of 4.0V D.C.