Home energy storage inverter battery all-in-one
advantage
Battery, inverter integrated design, no need to install multiple times, top handle and lower roller design, more convenient and labor-saving when moving
Using LifePO4 battery pack, the service life is 10~20 times of the traditional lead-acid battery, and the weight is only one-third of the same capacity lead-acid battery, LifePO4 battery is more environmentally friendly and will not produce heavy metal pollution
From first-line manufacturers such as EVE CATL and other international well-known manufacturers, after the purchase back, the company's quality inspection department will conduct secondary testing to ensure the quality of each lifepo4 battery, the product is equipped with BMS to protect the safety of the battery during charging and use
We have our own factory, production department and technology development department to support the customization of all battery products in our store, OEM/ODM can be
Grid module | |
Rated input voltage | 220/230Vac |
Input voltage range | (170Vac~280Vac) ±2% (90Vac-280Vac)±2% |
frequency | 50Hz/ 60Hz (Automatically detects) |
Frequency range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz); |
Overload/short circuit protection | disconnect |
efficiency | >95% |
Transfer time (bypass and inverter) | 10ms (Typical value) |
AC backfill protection | YES |
Maximum bypass overload current | 40A |
Inverter module | |
Output voltage waveform | pure sine wave |
Rated output power | 5000 (VA) |
Power Factor | 1 |
Rated output voltage | 230Vac |
Output voltage error | ±5% |
Output frequency range | 50Hz ± 0.3Hz 60Hz ± 0.3Hz |
Efficiency | >92% |
Overload protection | (102%< load <125%) ± 10%: report an error and shut down the output after 5 minutes; (125%< load <150%) ± 10%: report an error and shut down the output after 10 seconds; Load >150% ±10%: report an error and shut down the output after 5 seconds;
|
peak power | 10000VA |
On-load motor capacity | 4HP
|
Battery voltage range | 40.0Vdc~60Vdc ± 0.6Vdc (Under-voltage alarm / shutdown voltage / the over-voltage alarm/over-voltagerenew…LCD Screen can be set) |
Power saving mode | load≤50W |
Grid charging | |
maximum-charging current (can be set) | 60A |
Charging current error | ± 5Adc |
charging voltage range | 40 – 58Vdc |
Short circuit protection | Circuit breakers and blown fuses |
Circuit Breaker Specifications | 40A |
Overcharge protection | Alarm and turn off charging after 1 minute |
Solar change | |
Maximum PV ,Open circuit voltage | 145Vdc |
PV Operating voltage range | 60-145Vdc |
MPPT voltage range | 60-115Vdc |
Battery voltage range | 40-60Vdc |
Maximum input power | 4400W |
Solar charging current range (can be set) |
0-80A |
Charging short circuit protection | blow fuse |
Wiring protection | reverse polarity protection |
Maximum Hybrid Charge Current( PV+AC) | |
Maximum hybrid charge Current (can be set) | 0-140A |
Other Specification | |
Range of working temperature range | -15°C to 55°C |
Storage temperature range | -25°C ~ 60°C |
Humidity range | 5% to 95% (Three anti-paint protection) |
Noise | ≤60dB |
Heat dissipation | Forced air cooling, adjustable wind speed |
Communication interface | USB/RS485(WiFi/GPRS)/Dry Node Control |