FOQ Dual Power Automatic Transfer Switch Equipment For Generator 3 Phase
Automatic transfer switch equipment (ATSE), is a device integrated with the switching function and
logic control, truly perform electromechanical integration function, suitable for operating in the distribution
system of AC50Hz, rated voltage AC400V, conventional thermal current up to 3200A in mineral and
other enterprises. It provides the operation function of voltage detection, forcedly switching off “0” position,
manual emergency operation and etc, widely used to shift between normal power and standby power or
two loading equipment, or perform safe isolation and etc. the control circuit board will govern the motor
through logic commands, then motor will drive the operating mechanism of main switches, quickly closing
or opening or shift the lines, the safe isolation of main switch is obvious and legible by eye.
• Technical Data
♦Standard: IEC60947 ; GB14048-2008
♦Rated Working Voltage Ue : AC440V
♦Rated Connecting Capacity :10Ie
♦Rated Breaking Capacity : 8Ie
♦Control Supply Voltage : DC 24V 48V 110V ; AC 220V
Rated Heating Current | 100A | 160A | 250A | 400A | 630A | 1000A | 1250A | 1600A | 2000A | 2500A | 3200A | |
Rated Insulation Voltage Ui | 700V | 1000V | ||||||||||
Rated Impact Withstand Voltage Uimp | 8kV | 12kV | ||||||||||
Rated Operating Current Ie(A) | AC-31A | 100 | 160 | 250 | 400 | 630 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 |
AC-35A | 100 | 160 | 250 | 400 | 630 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 | |
AC-33A | 100 | 160 | 250 | 400 | 630 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 | |
Rated Short TIme Withstand Current Icw (kA) | 7 | 9 | 13 | 50 | 55 | |||||||
Rated Limit Short-circuit Current (kA) | 100 | 70 | 100 | 120 | 80 | |||||||
Control Supply Voltage (V) | DC 24V 48V 110V ;AC 220V | |||||||||||
Conversion Time (s) | 0.5 | 1 | 1.1 | 1.2 | 1.25 | 2.45 |
Wiring Diagram
Dimension
♦Electric key lock: Control switch internal control line power, when the electric lock is turned on, the switch can
be fully automatic, operation control, strong set "0" operation; when the electric lock is closed, the switch
can only be operated manually.
♦Operating handle: When using the operating handle to operate manually, the electric lock must be closed.
♦Padlock: Maintenance-only, that is, first use the operating handle to make the switch in the "0" position,
and then pick up the padlock mechanism and padlock, can be overhauled
♦Indicator: Indicates the working status of the switch.