Overview
E-link's EPD Outlet Metered Switched PDU with automatic transfer switching is the perfect solution for critical network installations that require remote power control and power supply redundancy on 85-265 AC equipment. E-link 's EPD series metered PDUs help you keep track of conditions at your data center, and can automatically notify you before things get out of hand. The EPD also allows you to automatically reboot outlets when attached devices cease to respond, disable outlets to reduce current consumption or switch on cooling devices to lower rack temperatures.
A comprehensive selection of monitoring features is also included; event alarms, outlet-specific metering, SNMP polling and other alarm functions help you to keep tabs on vital network elements, avoid costly service calls and maximize up time.
Features
Technical Indexes
Item | Parameter Requirements | Remark |
Working Power | 85V~265VAC | |
Working Frequency | 50Hz | |
Total Input | Specification please see the product label | According to Order Requirement |
Master Switch | Please see the product label | According to Order Requirement |
Voltage Measurement | Range:0~300V | Isolated |
Display Digits:0.01V | ||
Current Measurement | Input: Transformer | Isolated |
Range:0~30mA | Transformer output secondary current | |
Display Digits:0.01A | Primary Current | |
Branch off | 16A/250Vac Max. | |
Power on Sequence | Supports power-on sequence output from 1 to 8 branches | |
Power Measurement | Accuracy:Grade 1 | Active measurement |
Display Digits: 0.01kW | ||
Electricity Measurement | Accuracy:Grade 1 | Active measurement |
Display Digits:0.001kWh | ||
Temperature and Humidity Measurement | Temperature:0.01℃ Humidity:0.01%RH | Optional: But with sensors |
Communication Port | RS485 port, Modbus RTU Communication Protocol | Optional: uplink / downlink |
Display | OLED Screen, Blue text on black / White text on black | Optional |
Alarm Function 1 | Under-voltage, over-voltage, over-current, power out-of-limit alarms | Optional |
Alarm Function 2 | Temperature and humidity alarm | Optional: But with sensors |
Alarm Function 3 | Access control 1, access control 2, smoke detection and flood alarms. | Optional: But with sensors |
Alarm Function 4 | Lightning protection failure detection and lightning protection count | Optional, but with a lightning protection module |
Photosensitive Detection | Normally used for automatic lighting with extended functions | Optional, but with an interface expansion module |
Physical | Description | Remark |
Length | PDU: 440mm; PDU length including Mounting Brackets 482.6mm | |
Height | 1U Standard (Actual Height: 44.2mm) | |
Width | 163mm |
Items | Environment Requirements | Remark |
Working Environment | Indoor | |
Power Limit | Derating should be used at altitudes above 2000 meters |
Application
Ordering Information
Model Number | Input | Output | Output Interface |
Control | |||
LNK-IPMU-HS19-1U-CR1.8-Q1-G10A8-MTX | Micro Circuit Breaker 1P,16A | GB2015,Max=13A,8CH Control output | GB1002(10A/250V) |
LNK- IPMU-HS19-1U-CR1.8-Q1-C13A8-MTX | Micro Circuit Breaker 1P,16A | IEC320-C13(Cable anti falling),Max=13A,8CH Control output | IEC60320 C13 |
LNK-IPMU_HS19_1U_CR1.8_Q1_Y16A8_MTX | Micro Circuit Breaker 1P,16A | Universal plug Max=16A,8CH Control output | (16A/250V) |