UT-King' offers a variety of Planar lightwave circuit (PLC) splitters, which are an optical power management device that is fabricated using silica optical waveguide technology to distribute optical signals from the Central Office (CO) to multiple premise locations.
ABS Type PLC splitter are most commonly used in the PON networks. They provide complete protection for inner optical components and cable, and are designed for convenient and reliable installations.
With high volume usage, the PLC splitters are mainly used for various connection and distribution products (outdoor fiber distribution boxes) or network cabinets. Ideal for EPON, GPON, FTTH/FTTX networks
PLC Splitter is a component that splits the optical light power from one route into different routes. Molex PLC Splitter offers premium factory controlled optical performance on a variety of connectors that enable fast, economical installation.
1x32 Planar Lightwave Circuit (PLC) ABS Box Type Splitter with SC/APC or SC/UPC Termination. Fabricated using silica optical waveguide technology to distribute optical signals accurately and evenly with minimal loss providing a low cost light distribution solution with small form factor and high reliability.
Specification
Item | 1x2 | 1x3 | 1x4 | 1x6 | 1x8 | 1x12 | ||||||||||
Operating Wavelength(nm) | 1260-1650 | |||||||||||||||
Fiber Type | G657A1 or as customers' order | |||||||||||||||
Connector | SC/FC/LC | |||||||||||||||
Ferrule section | UPC/APC | |||||||||||||||
Insertion loss(dB) | ≤4.1 | ≤6.4 | ≤7.4 | ≤9.3 | ≤10.5 | ≤12.8 | ||||||||||
Loss uniformity(dB) | ≤0.4 | ≤0.4 | ≤0.6 | ≤1.6 | ≤0.8 | ≤1.2 | ||||||||||
Return Loss(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ||||||||||
Polarization Dependent Loss(dB) | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.25 | ||||||||||
Directivity(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ||||||||||
Temperature correlation loss -40~85℃(dB) | ≤0.5 | ≤0.5 | ≤0.5 | ≤1.5 | ≤0.5 | ≤0.5 | ||||||||||
Size(mm)(LxWxH) | 40×4×4 | 60×7×4 | ||||||||||||||
Working Temperature(℃) | -40~85 | |||||||||||||||
Storage Temperature(℃) | -40~85 | |||||||||||||||
Item | 1x16 | 1x24 | 1x32 | 1x48 | 1x64 | 1x128 | ||||||||||
Operating Wavelength(nm) | 1260-1650 | |||||||||||||||
Connector | SC/FC/LC | |||||||||||||||
Ferrule section | UPC/APC | |||||||||||||||
Fiber Type | G657A1 or as customers' order | |||||||||||||||
Insertion loss(dB) | ≤13.8 | ≤15.8 | ≤16.8 | ≤18.7 | ≤20.5 | ≤24.1 | ||||||||||
Loss uniformity(dB) | ≤1.2 | ≤1.5 | ≤1.5 | ≤2.0 | ≤2.0 | ≤2.5 | ||||||||||
Return Loss(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ||||||||||
Polarization Dependent Loss(dB) | ≤0.25 | ≤0.3 | ≤0.3 | ≤0.4 | ≤0.4 | ≤0.4 | ||||||||||
Directivity(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ||||||||||
Temperature correlation loss -40~85℃(dB) | ≤0.5 | ≤0.5 | ≤0.5 | ≤1.5 | ≤0.5 | ≤0.5 | ||||||||||
Size(mm)(LxWxH) | 60×7×4 | 60×12×6 | N/A | |||||||||||||
Working Temperature(℃) | -40~85 | |||||||||||||||
Storage Temperature(℃) | -40~85 | |||||||||||||||
Item | 2x2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | 2x128 | |||||||||
Operating Wavelength(nm) | 1260-1650 | |||||||||||||||
Fiber Type | G657A1 or as customers' order | |||||||||||||||
Connector | SC/FC/LC | |||||||||||||||
Ferrule section | UPC/APC | |||||||||||||||
Insertion loss(dB) | ≤4.5 | ≤7.9 | ≤10.8 | ≤14.1 | ≤17.3 | ≤21.1 | ≤24.8 | |||||||||
Loss uniformity(dB) | ≤0.9 | ≤1.1 | ≤1.2 | ≤1.5 | ≤1.8 | ≤2.2 | ≤2.5 | |||||||||
Return Loss(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |||||||||
Polarization Dependent Loss(dB) | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.4 | ≤0.4 | ≤0.4 | |||||||||
Directivity(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |||||||||
Temperature correlation loss -40~85℃(dB) | ≤0.5 | ≤0.5 | ≤0.5 | ≤1.5 | ≤0.5 | ≤0.5 | ≤0.5 | |||||||||
Size(mm)(LxWxH) | 50×4×4 | 60×7×4 | N/A | |||||||||||||
Working Temperature(℃) | -40~85 | |||||||||||||||
Storage Temperature(℃) | -40~85 |