Fast Optical Power Meter Probe Computer Controlled 850 ~ 1700nm
summarize:
The sampling period of the U8721 high-speed optical power meter module of Guangzhou Youxi can reach the uS level, and the data can be acquired and processed more quickly. The power meter module adopts USB communication interface, which can communicate with PC directly, display data and set parameters through configuration software.
The U8721 high speed optical power meter module can be used in high precision WDM components, optical waveguide grating array AWG components, planar optical waveguide PLC components, WSS, OPM, DPSK, optical amplifier EDFA and other general optical fiber optical measurement applications. Compared with other models of Guangzhou Youxi power meter, U8721 has the characteristics of high-speed sampling, and small shape, especially suitable for assembly into multi-channel optical power meter sampling system.
peculiarity :
Fast startup and high measurement accuracy
Wide dynamic power measurement range
A wide selection of power ranges and channels
USB communication interface, high speed and convenient
Affordable
Apply :
WDM, GFF, AWG, PLC device test
Insert loss, return loss measurement
Optical fiber sensor, optical fiber cable test
Polarization mode dispersion PMD and polarization dependent loss PDL measurement
Optical fiber, communication R&D laboratory test
U8721C Product regulation
Model | U8721C | ||||
Sensor Element | InGaAs | ||||
Wavelength Range | 850 ~ 1700 nm | ||||
Calibration wavelength | 850 / 980 / 1310 / 1510~1640nm Continuous calibration | ||||
Power Range (dBm) | + 5 ~ -80 | ||||
Power sampling period(Rate) | 10 us(100KHz) | ||||
Application Fiber Type | Standard SM and MM | ||||
optical Input Interface | Supporting bare fiber joint or FC/LC/SC Adapter | ||||
Absolute Uncertainty (accuracy) at reference condition | ± 4% (1200 nm ~ 1610 nm) | ||||
Relative Uncertainty (accuracy) at reference condition | < 0.02 dB typical value | ||||
Linearity (power) | ≤± 0.06dB (1200 ~ 1610 nm, + 0 ~ -60dBm) | ||||
Return Loss | > 40 dB | ||||
Communication Interface | +Trig | ||||
Calibration period | 2 years | ||||
Operation Temperature | 0 ~ +40℃ | ||||
Storage Temperature | -30 ~ +80℃ | ||||
Dimensions | 52mm H,60 mm W,150 mm D | ||||
Weight | 1.0 kg |
Other users will ask the following questions:
1.What fiber link is needed for light source and power meter execution?
A light source and a power meter are required to perform the most important measurement of a fibre optic link, the total insertion loss of that link. Basically, you compare the amount of light going into one end of the fibre with the amount of light coming out of the other end of the fibre.
.
2.What is good dBm for fiber?
Positive dBm means power greater than 1mw and negative means less than 1mw. A good laser source for a singlemode link will have a power output of ~ +3 to +6 dBm - 2-4mw - coupled into the fiber. A VCSEL for multimode links should have a power around 0dBm - 1mw.