Ruggedized Flat Twin Duplex Fiber Optic Patch Cable LC-LC Multimode, extra outer LSZH jacket covered
LSZH Ruggedised flat twin fiber patch cords with an additional outer jacket for durability in singlemode (OS1) and multimode (OM1, OM2, OM3 & OM4) available , this offers extra protection and makes the fibre patchcord more robust than the standard duplex patchcord.
It is used for indoor distribution and as pigtail communication equipment. These leads are normally used where the fibre patchcord is being installed in ducting or on long lengths of cable trays and that extra bit of protection is required for installation purposes.
These leads are special order leads and are made to order as per the requirements of the project.
Characteristics:
1. Two single-fiber as basic unit .flat twin configuration.
2. Tight buffer.(900um or 600um)
3. Single-cable with independent strength member.
Application:
1.Can be installed conveniently and perated simply.
2. Suitable for communication equipment served.
3 Adopted to indoor distribution.
4. As pigtail of communication equipment.
Order options:
1. Fiber type: single mode or Multi mode
2. Outer jacket: PVC or LSZH
3. Aramid yarn: Chinese yarn or Kevlar yarn
4. Cable size: tight buffer size(find it on the first table)
Technical Parameters:
Out sheath Diameter | Tight buffer Diameter | Weight | Minimum allowable Tensile Strength (N) | minimum allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage temperature | |||
(MM) | (MM) | (KG) | short term | long term | short term | long term | short term | long term | (°C) |
3.0×5.0 | 1.8 | 56.00 | 800 | 300 | 1000 | 500 | 20D | 10D | -20+60 |
3.2×5.6 | 2.0 | 68.00 | 800 | 300 | 1000 | 500 | 20D | 10D | -20+60 |
5.0×8.0 | 2.8 | 87.00 | 800 | 300 | 1000 | 500 | 20D | 10D | -20+60 |
Optical Characteristics: | ||||
Fiber Sort | Multimode | G.651 | A1a:50/125 | Graded-index fiber |
A1b:62.5/125 | ||||
Singlemode | G.652(A,B,C) | B1.1:Conventional fiber | ||
G.652D | B2: Zero dispersion shifted | |||
G.655 | B1.2 :Cut-off wavelength shifted | |||
G.657(A1,A2 ,B3) | B4: Main technical data for positive dispersion shifted single-mode fiber |
Fiber Cladding:
Fiber Type (Core/Dladding Dimension) | 8.3/125, 50/125, 62.5/125 |
Transmission Characteristics:
Fiber Mode | SMF | 50/125 | 62.5/125 |
Wavelength | 1310/1550(nm) | 850/1300(nm) | 850/1300(nm) |
Max Attenuation (dB/km) | 0.45/0.30 | 3.5/1.5 | 3.5/1.5 |
AVG. Attenuation (dB/km) | 0.40/0.25 | 3.0/1.0 | 3.0/1.0 |
Min Bandwidth (MHz/km) | -- | 400/400 | 160/500 |
Environmental Characteristics:
Storage/Operating Temperature | -20ºC~+60ºC |