Specifications of 60ch 100GHz AAWG Module
1.Application Note
The specifications serve for C-band 100GHz Flat-top MUX/DEMUX in DWDM system.
The AWG module is athermal.
2.Optical Specifications
2.1Optical signal transmission diagram
|
Figure 1 Optical signal transmission characteristics
2.2Optical Specifications
Table 1 Optical Specifications
Connector loss is included.
Table 2 Channel Plan
Type | First Channel Frequency (THz) | Last Channel Frequency (THz) | First Channel Wavelength (nm) | Last Channel Wavelength (nm) |
EVEN | 196.6 | 190.7 | 1524.885 | 1572.063 |
Table 3 Channels List: Passbands for 60 channel AAWG
3.Environmental Conditions and Maximum Ratings
Table 4 Environmental conditions
Parameters | Notes | Specifications | Units | ||
Min | Typ | Max | |||
Operating Temperature | -5 | +65 | °C | ||
Storage Temperature | -40 | +85 | °C | ||
Relative Humidity | 0 | 95 | % |
Figure 2 AAWG planar drawing
Parameters | Notes | Specifications | Units | ||
Min | Typ | Max | |||
Optical Fiber Terminations | LC/UPC | ||||
Package Size | (L*W*H) | 120*70*10.5 | mm³ | ||
Common Fiber Length | Including connector | L: 500±50 | mm | ||
Common Fiber Type | 900μm loose tube G657A2 | ||||
Fiber from module to fan-out | L1: 500±50 | mm | |||
Fiber from fan-out to connectors | Including connectors | L2: 500±50 | mm | ||
Channel Fiber Type | 900μm loose tube G657A2 | ||||
Figure 3 AAWG module structure and fiber length illustration
Figure 4 Fan-out planar Drawing