Specifications
Brand Name :
Dawnergy
Model Number :
DA-ODU48-SC-D
Place of Origin :
China
MOQ :
10
Price :
50
Payment Terms :
L/C, D/A, D/P, T/T
Supply Ability :
100 pre/day
Delivery Time :
30 days
Brand :
Dawnergy
Product :
2U ODF Unit Distribution Type
Max. Connect :
48 SC/UPC
Structure :
Rotating type
Adapter Type :
SC/UPC
Box Material :
Cold rolled steel; powder coated
Splicing Tray :
24cores tray
Max. Dimensions (mm) (W x D x H) :
480 x 260 x 2U
Description

DA-ODU48-SC-D 2U ODF Unit Distribution Type

Dawnergy’s rotating type rack-mount fiber optic ODF unit are widely applied in Local Central Office. These are used for fiber optic cable fixation, protection, cable termination, patching etc. 19-inch rack mount for SC adapters. Max up to 48cores. The drawer is the holding board only for adapters distribution, easy to withdraw the fibers when testing and distributing.

Features

  • Standard size, light weight and reasonable structure
  • Rotating drawer for easy cable management(Designed in a hinged style (sliding and rotating around a fixed axis of rotation) to easily perform connection operations)
  • Compact design for space saving
  • Designed with an open structure to facilitate operations when fixing cables inside the rack frame.
  • The ODF Module when installed in the cabinet arranged to facilitate installation, connection, inspection and maintenance operations
  • Various panel plate to fit different adapter interface
  • Easy for management and operation
  • The ODF Module are designed to be installed independently of each other in the cabinet

Applications

  • Telecommunications subscriber loop
  • Fiber to the home (FTTH)
  • LAN/WAN
  • CATV

ODF Distribution Module Specifications

Parameters Specification
Max. Connect 48 SC/UPC
Structure Rotating type
Adapter Type SC/UPC
Minimum radius bending of fiber in/out 35mm
Material of Box , and panel adapter Low carbon steel (mild steel), powder coated, Light Grey color
Splicing Tray No
Dimensions (mm) (W x D x H) 480 x 260 x 2U ( use for rack 19inch standard)

Drawing (mm)

DA-ODU48-SC-D 2U ODF Unit Distribution TypeDA-ODU48-SC-D 2U ODF Unit Distribution TypeDA-ODU48-SC-D 2U ODF Unit Distribution Type

Splicing Type ODU

Adapter Specifications ( Dawnergy’s product)

Parameter Specification
Quantity Adapter 48 pcs
Material Cold rolled steel,powder coated
Color Blue (UPC)
Type SC/UPC with dust cap
Material Housing make of plastic, and core make of Zirconia
Insertion Loss (dB) ≤ 0.2
Durability (dB) 500 times plugging
Operating Temperature (°C) -40 ~ +85
Storage Temperature (°C) -40 ~ +90

Ordering Information

Model Name Description
DA-ODU48-SC-D ODF Module

Full accessories for 48FO, Adapter SC/UPC, all product made from Dawnergy brand name

Installation Manual

1. Overview

1.1. Product Usage

Dawnergy’s DA-ODF unit are designed and manufactured according to the international standard and implement such functions as the inlet, fixation, and stripping protection for optical cables, protection for optical fibers storage and management of fiber patch cord, fixed connection and cross connection of optical fibers. Meanwhile, value-added modules such as optical splitter and wavelength division multiplexer can be installed if required by the customer. They can find wide application in optical fiber communication networks and are applicable to central offices and cross-connecting points in an optical access network.

1.2. Operating Principle

DA-ODU48-SC-D 2U ODF Unit Distribution Type

1.3. Structural Features

  • Full front operation for optical fiber distribution and dispatching;
  • 19’’ installation of racks;
  • Suitable for ribbon or non-ribbon cables;
  • Adapter insertion installation, suitable for multiple adapters such as SC.
  • Adapters can be installed in an angle of 30 degrees to the front to the cabinet to prevent direct arc light from hurting your eyes and to facilitate cabling.
  • Ribbon cables provide dedicated stripping protection connector to make the protection of bare fibers and the fixation and grounding of optical cables more perfect and reliable.
  • The 48-core ODF unit 2U with SC/UPC.

1.4. Structure

DA-ODU48-SC-D 2U ODF Unit Distribution Type

Size and Capacity

Model Name

Size(mm)

(H×W×D)

Remarks
DA-ODU48-SC-D ODF Unit 2U×480×260 Distribution Type

2. Technology Specifications

2.1. Operating conditions

  • Operating temperature: indoor type: -5ºC ~ +40ºC.
  • Storage temperature: -25ºC ~ +55ºC.
  • Relative humidity: 85% (+30ºC).
  • Atmospheric pressure: 70 kPa ~ 106 kPa

2.2. Insulation resistance

Insulation resistance between grounding device and cabinet > 2x104MΩ/500V(DC)

2.3. Withstanding voltage:

Withstanding voltage between grounding device and cabinet no less than 3000V(DC)/1min, no breakdown, no flying arc.

3. ODF Unit Installation Accessories and Tools

3.1 Mounting rack screws

DA-ODU48-SC-D 2U ODF Unit Distribution Type

3.2 Installation Tools

DA-ODU48-SC-D 2U ODF Unit Distribution Type

4. Operation

Step 1: ODF Unit Installation and fixation on the rack.

DA-ODU48-SC-D 2U ODF Unit Distribution Type

Step 2:Open the front door. Pull out the rotating disc from the unit.

DA-ODU48-SC-D 2U ODF Unit Distribution Type

Step 3: Lead the patchcord enters the ODF unit and connect to the adapters.

DA-ODU48-SC-D 2U ODF Unit Distribution Type

  1. Input patchcord

Step 4: Connect and arrange the output patchcord.

DA-ODU48-SC-D 2U ODF Unit Distribution Type

  1. Output Patchcord

Step 5: Push in the rotating disc from the unit and close the front door.

5. Fault Analysis and Troubleshooting

Serial Common Fault Cause Analysis Troubleshooting and Remarks
1 Disconnection of transmission line or poor transmission effect Inappropriate bending radius causes permanent physical deformation to the optical cable/fiber and increases transmission loss During construction, the engineering personnel must pay attention to the protection of bending radius of fibers (bends and bottlenecks for cable inlet and outlet in racks) and ensure that the cable routing is reasonable
Loose connection, great loss of optical fiber active connectors (adapters, pigtails/fiber patch cord) Check whether all threaded or plug-in mechanical connectors are firm and meet their respective standards
2 Optical fibers are easy to fall off or not reliable The most fragile part of the optical fiber/cable lies in the position where abrupt physical structure change happens, which may affect the security and reliability of the entire network

Be careful in cable fixing, stripping protection, secure grounding, and splicing point protection; no error or omission is allowed.

3 Redundant fiber storage disorder Caused by insufficient cable length in design or careless work of construction personnel Sufficient fiber core shall be reserved during product planning. Adjust cables during construction to make cables in the rack clear and neat.
4 Unclear labels Disorder caused by the dismantle during construction or maintenance Clear labeling and detailed records

6. Packaging, Transportation and Storage

6.1 Packaging

In DA-ODF-Unit of products are packed in cartons. Products (including accessories) are packed according to packaging specifications and are damp-proof and shock proof. Accessories and spare parts are placed into respective bags and then placed in the packing box.

6.2 Transportation

After being packed in wooden boxes/cartons, DA-ODF-Unit products can be transported by motor vehicle, train, ship, or airplane. Prevent the products from collision, falling, rain, snow and direct sunshine during transportation.

6.3 Storage

The DA-ODF-Unit products should be stored in a dry and ventilated warehouse without any erosive gases. The storage temperature should be -25ºC ~ +55ºC.

Send your message to this supplier
Send Now

DA-ODU48-SC-D 2U ODF Unit Distribution Type

Ask Latest Price
Brand Name :
Dawnergy
Model Number :
DA-ODU48-SC-D
Place of Origin :
China
MOQ :
10
Price :
50
Payment Terms :
L/C, D/A, D/P, T/T
Contact Supplier
DA-ODU48-SC-D 2U ODF Unit Distribution Type

Dawnergy Technologies(Shanghai) Co., Ltd.

Verified Supplier
6 Years
shanghai, shanghai
Since 2015
Business Type :
Manufacturer
Total Annual :
60000000-62500000
Certification Level :
Verified Supplier
Contact Supplier