The FTTA & FTTH water-proof connector is factory-terminated, environmentally sealed and hardened connectors to reduce the cost and the time of drop cable deployment in optical access networks. The patchcord is specifically designed to significantly reduce required drop cable installation and compatible to active device. The patchcord provide a robust and sealed connection solution for FTTA and FTTH connectivity.
Application
Features
Patchcord Specifications
Parameters | Specifications |
Connector Type | FTTA & FTTH water-proof connector |
Fiber Type | SM or MM |
Fiber Core | 1,2,4~24 |
Insertion Loss (dB) | Depend on water-proof connector type |
Material of Outer Jacket | LSZH, PE, PVC, PA, TPU or customized |
Cable Length (m) | Customized |
Operating Temperature (℃) | -40 ~ +70 |
5.0mm Double Jacket Outdoor Cable Specifications
Cable Count | Out sheath Diameter (mm) | Weight (kg) | Minimum Tensile Strength (N) | Minimum Crush Load (N/100mm) | Minimum Bending Radius (mm) | Storage Temperature (℃) | |||
1~2 | 5.0±0.2 | 26 | Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | -20~+70 |
800 | 400 | 2000 | 1000 | 20D | 10D |
4x7 mm Flat Outdoor Cable Specifications
Cable Count | Out sheath Diameter (mm) | Weight (kg) | Minimum Tensile Strength (N) | Minimum Crush Load (N/100mm) | Minimum Bending Radius (mm) | Storage Temperature (℃) | |||
1 |
(4.0±0.2) x (7.0±0.2) |
42 | Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | -20~+70 |
1350 | 400 | 2200 | 1000 | 20D | 10D |
2x3 mm Flat Outdoor Cable Specifications
Cable Count | Out sheath Diameter (mm) | Weight (kg) | Minimum Tensile Strength (N) | Minimum Crush Load (N/100mm) | Minimum Bending Radius (mm) | Storage Temperature (℃) | |||
1 |
(2.0±0.1) x (3.0±0.1) |
8 | Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | -20~+70 |
100 | 50 | 500 | 100 | 20D | 10D |
Optical Characteristics
Item | Parameter | Reference | |
Single mode | Multimode | ||
Insertion Loss | Maximum≤0.3dB | Maximum≤0.3dB | IEC 61300-3-34 |
Return Loss |
≥60dB (APC) ≥50dB (UPC) |
≥30dB (UPC) | IEC 61300-3-6 |
End-Face Geometry
Item | UPC | APC |
Radius of curvature (mm) | 7~25 | 5~12 |
Fiber height (nm) | -100~100 | -100~100 |
Apex offset (um) | 0~50 | 0~50 |
APC angle (°) | 8±0.2 | |
Key error (°) | 0.2 max |
Test Conditions Reference
Package (Thin film winding and carton packing)