Automatic Liquid Dispenser With time control glue dispensing machine/damu glue dispenser/glue dispensing robot
Automatic Liquid Dispenser With time control,topush the liquid pneumatically,controlled by timer, to be sure the same dispensing drops and dispensing cycle time,regulated the air pressure with suitable tip at your equipments of the different liquids as glues,greases,solder pqstes.Applied for 10 types of steel tips and 5 types of plastic tips for various cus tome rs”needs..
Technical data
1.Timer :programmable:0.01~1s; 0.1~10s;
0.2~20s; 0.3~30s;
2.Cycle lnitiation :Maintained or Momentary
3.Repeat Tolerance: + 0.5%
4.Size :235*225*63 mm
5.Weight :2.20kg
6.Voltage input :220~240V 50Hz AC
7.lntemal Voltege :24V DC
8.Minimum Deposit :0.01ml
9.Air lnput :2.5~7 bar (35~100ps i)
10.Air Output :0.1~5.5bar (1~78ps i )
Features
Features Function
1.power Switch Turns unit on and off.llluminated
to indicate “NO”position.
2.Air pressure Controls and lndicates air pressure to
Regulator/gauge the dispense circuit (the handie of
Regulator should be pulled out to adjust.)
3.Mode Switch places the dispense circuit ln automatic
Or manual shot mode.
4.Timer Control Adjust the shot of the Auto dispense mode.
5.Vacuum Control Adjust the intensity of “suck back”
Vacuumapplied to the dispense circuit.
6.Dispense Outlet provid a quick connect receptacle tor
Dispense air circuit,
7.Socket of Foot-switch Activates the dispense circuit.
8.Air-in tube High-pressured air input.
9.Dispensing control Four grades for the dispensing cycle time.
Dotting range regulated
Under the”auto”mode,full clockwise turn of timer knob,to step the foot switch,as:
Drip switch is on at 1:dispensing time >1s
Drip switch is on at 1,2:dispensing time>10s
Drip switch is on at full grades:dispensing tme>30s
Customer can adjust according to time-being requirements.
Internal al air pressure regulated:
On the air pressure regulated knob,regulateb intemal air
Pressure,on the air pressure gauge,general used between 0.1-2.7 bar(1-40 psi)
Vacuum control regulated
On the vacuum contyol knob,regulated the ending dot in the air
Reflation,avoid dotting connected with others.
Setup
1. Connect the 7bar dry and filtered air supply to the units air input plug.
2. Putthe materidl end parts in barrel properly,(material height notexcess the waming line,otherwise spend more)see the fig3.
3. Insert the power plug,foot switch plug and hose plug into the concemed sockets.
4. Operation
1. Tum the unit on and indicator at”on”position lighte up.
2. Pull the air pressure yrgulator knod outward and tum clockwise until the desired air pressure is indicated.
3. As the need of switch on the “MAN” or AUTO”mode,then it,s ready to be operated.
Caution
The dispensed material maybe toxic and /or hazardous ,refer to material manufacture’s bulletin for proper handing and safety precautions.
Maintenance
To assure trouble free operation ,the following points should be followed: