Cable Mechanical characteristic:
Cable type | Diameter (mm) | Weight (kg/km) | Tensile strength Long/short term (N) | Crush Resistance Long/Short Term(N/100mm) | Bending radius Dynamic/static (mm) | Storage temperature ( ℃ ) |
GYTA-2~60 | 9.0 | 100 | 600/1500 | 300/1000 | 20D/10D | -20~+70 |
GYTA-62~72 | 10 | 110 | ||||
GYTA-74~96 | 11 | 130 | ||||
GYTA-98~120 | 13 | 145 | ||||
GYTA-122~144 | 15 | 195 |
Main mechanical & environmental performance test:
Item | Test Method | Acceptance Condition |
Tensile Strength IEC 794-1-2-E1 | - Load: Short term tension - Length of cable: about 50m | - Fiber strain £ 0.15% - Loss change £ 0.1 dB @1550 nm - No fiber break and no sheath damage |
Crush Test IEC 60794-1-2-E3 | - Load: Short term crush - Load time: 1min | - Loss change £ 0.05dB@1550nm - No fiber break and no sheath damage. |
Impact Test IEC 60794-1-2-E4 | - Points of impact: 3 - Times of per point: 1 - Impact energy: 5J | - Loss change £ 0.1dB@1550nm - No fiber break and no sheath damage |
Temperature Cycling Test YD/T901-2001-4.4.4.1 | - Temperature step: +20℃→-40℃→+70℃ →+20℃ - Time per each step: 12 hrs - Number of cycle: 2 | - Loss change £ 0.05 dB/km@1550 nm - No fiber break and no sheath damage. |
Characteristics:
1. Good mechanical and temperature performance.
2. High strength loose tube that is hydrolysis resistant.
3. Special tube filling compound ensure a critical protection of fiber.
4. Specially designed compact structure is good at preventing loose tubes from shrinking.
5. PE sheath protects cable from ultraviolet radiation.
6. The following measures are taken to ensure the cable watertight:
a: Steel wire used as the central strength member
b: Loose tube filling compound
c: 100% cable core filling
d: APL moisture barrier
Application:
1. Adopted to outdoor distribution.
2. Suitable for aerial, pipeline laying method.
3. Long distance and local area network communication.