Absolute Maximum Ratings | |||||
Parameter | Symbol | Min. | Max. | Unit | Note |
Supply Voltage | Vcc | -0.5 | 3.6 | V | |
Storage Temperature | TS | -40 | 85 | °C | |
Relative Humidity | RH | 0 | 85 | % | |
Rx Damage Threshold,per Lane | PRdmg | 5.5 | dBm |
Recommended Operating Conditions | ||||||
Parameter | Symbol | Min | Typ | Max | Units | Note |
Operating Case Temperature | TC | 0 | - | +70 | °C | |
Power Supply Voltage | VCC | 3.14 | 3.3 | 3.47 | V | |
Data rate | 103.125 | 112 | Gb/s | |||
Link Distance (OM3) | 70 | m | ||||
Link Distance (OM4) | 100 | m |
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
Transmitter | ||||||
Signaling rate per lane | DRPL | 25.78125 ± 100 ppm | Gb/s | |||
Differential pk-pk input voltage tolerance | Vin,dpp | 900 | mV | |||
Single-ended voltage tolerance | Vin,pp | -0.35 | +3.3 | V | ||
Module stress input test | Per IEEE 802.3bm | |||||
Receiver | ||||||
Signaling rate per lane | DRPL | 25.78125 ± 100 ppm | Gb/s | |||
Differential data output swing | Vout,pp | 400 | 800 | mV | ||
Eye width | Ew | 0.57 | UI | |||
Vertical eye closure | VEC | 5.5 | dB | |||
Differential termination mismatch | Tm | 10 | % | |||
Transition time, 20% to 80% | Tr,Tf | 12 | ps |