High Return Loss LZSH Jacket Duplex 2M Fiber Optic Patch Cables FC To FC
1. Basic Introduction:
FC/UPC-FC/UPC Multimode Patch Cord has 100% Insertion, Return Loss, End Face, and Interference Inspection.
The fiber connectors at both ends contain fiber-optic connection lines are fiber optic patch cords, and the heads at both ends of the fiber optic patch cord can be the same or different, which makes the fiber optic cord variety varied. But the mode of the header needs to be the same, such as single-mode to Singlemode, multimode to multimode.
FC fiber patch cables are widely used in the optical path, with metalheads and ceramic ferrule. They have good stability and higher pluggable times than plastic heads. 0.9/1.8/2.0/2.8/3.0mm cable diameter can be selected.
2. Patch Cord Benefit & Features:
3. Fiber Optic Patch Cord Applications:
4. Specification&Technology Parameter
Parameters | Value | ||||
Connector Type | LC/UPC,LC/UPC | ||||
Center Wavelength(nm) | 1310 or 1550 | ||||
Max.Insertion Loss(dB) | 0.3 | ||||
Min.Extinction Ratio(dB) | 23 | ||||
Min.Return Loss(UPC) (dB) | 50 | ||||
Min.Return Loss(APC) (dB) | 60 | ||||
Key Orientation | Slow Axis | ||||
Axis Alignment(deg) | ±3 | ||||
Operating Temperature(℃) | -20~+70 | ||||
Storage Temperature(℃) | -40~+85 | ||||
FIber Type | PM Panda Fiber |
* For Device with connector.IL is 0.3dB higher,RL is 5dB lower,ER is 2dB lower.
* The default connector key is aligned to the slow axis.
5. LC to FC Connector Specification& Technology Parameter:
Parameter | Unit | Index | |||
End-Face Type | PC | UPC | APC | ||
IL | dB | SM: ≤0.3;MM ≤0.1 | |||
Repeatability | dB | ≤0.1 | |||
interchangeability | dB | ≤0.2 | |||
RL | SM | dB | ≥50 | ≥50 | ≥50 |
MM | dB | ≥36(Without APC connector) | |||
Mating Times | >1000 | ||||
Operating Temperature | ℃ | -40~ +80 |
* EX: OFC-D-LA-LA-09-0-1.0
6. FC Connector Ordering Information:
OFC | -X | -XX | -XX | -XX | -X | -X |
S: Simplex D: Duplex | FA:FC/APC FC:FC/UPC FP:FC/PC | FA:LC/APC FC:LC/UPC FP:LC/PC | 09:0.9mm 20:2.0mm 30:3.0mm | 0:G652D 1:G657A 2:50/125 3:62.5/125 4:others | 0.5:0.5m 1.0:1.5m 10:10.0m | |
Fiber Mode | Connector Type | Connector Type | Cable Diameter | Flange Type | Fiber Length |
* EX: OFC-S-FA-FC-09-1-0.5
7. Polish Type Abbreviations:
Note: The polish type affects the amount of back reflection, also known as reflectance.
PC - Physical Contact. Polished to create a slight dome at the end of the ferrule that helps to maximize the signal being transmitted.
UPC - Ultra Physical Contact. More extensive polishing than the PC type, a greater dome shape is created that further helps to maximize the signal being transmitted.
APC - Angled Physical Contact. Polished at an angle rather than a dome shape. This is the most efficient polish type.