35 MM Fiber Shrink Tube Heat Shrinkable Splice Protector With Strength Member
Fiber optic Splice Sleeve Sell Points:
Fiber Splice Heat Shrink Characteristics:
Specification & Characteristics:
Project | Test Method | Typical Data |
The Tensile Strength | ASTM d 2671 | 18Mp |
Tensile Rate | ASTM d 2671 | 700% |
Density | ISO R1183D | 0.94g/cm3 |
Compressive Strength | IEC 243 | 25KV/mm |
Volume Resistivity | IEC 243 | 1015Ω |
The Dielectric Constant | IEC 243 | 2.5 |
The Longitudinal Shrinkage Rate | ASTM d 2671 | ≤5% |
The Rate Of Partial Wall | ASTM d 2671 | 10% |
Size | Routine | 15,25,35,40,43,45,50,60 |
Unconventional | Micro 15mm, 8 core 24mm, 12 core 40mm | |
Operating Temperature | (-40 -+85℃) | |
Initial Shrinkage Temperature | 120℃ |
Fiber Fusion Splice Heat Shrink Application:
1. Fusion splicing
2. Fiber cable protecting
3. FTTH system
4. Rack-mount & Wall-mount terminal box
5. Optical fiber switch box and so on continue protection
6. All types of fiber cables
More Types Of Fiber Optical Fusion Splice:
Item | Description | Sleeving | Outer tube (Heat-shrinkable) | ||||
Diameter (Before shrink) | Diameter (After shrink) | Length | Inner Diameter | Outside diameter | Length | ||
1 | Fiber Protection Sleeves _11mm_φ1.9_Without Strength Member | 1.9±0.1 | 1.25±0.1 | 11±0.1 | 1.4±0.1 | 1.9±0.1 | 11±0.1 |
2 | Fiber Protection Sleeves _15mm_φ1_with Strength Member | 1.8±0.1 | 1.4±0.1 | 15±0.1 | 1.5±0.1 | 1.8±0.1 | 15±0.1 |
3 | Fiber Protection Sleeves _20mm_φ3_Without Strength Member | 3.9±0.1 | 2.5±0.1 | 20±0.1 | 3.4±0.1 | 3.9±0.1 | 20±0.1 |
4 | Fiber Protection Sleeves_20mm_φ4_Without Strength member | 4.4±0.1 | 3.0±0.1 | 20±0.1 | 4.0±0.1 | 4.4±0.1 | 20±0.1 |
Geehe Comm Serivce :
1) High Environmental Stability
Low insertion loss, low polarization dependent loss, low back reflection, and good uniformity
2) Compact Structure
Small size, it can be directly installed in a variety of transfer box and just take up little space
3) Strict Quality Control
We guarantee that every product to the hands of customers is subject to stringent testing standards