1x64 Fiber PLC Splitter Tray Compact Design Installed in Cross Connection Cabinet and ODF
1x64 Fiber PLC Splitter Tray, G.657A Fiber, FC, SC, ST & LC connectors for choice, is a packaged system that PLC splitter input fibers and output fibers are preinstalled on a tray which easily fit within ODF (Optical Distribution Frame), the Cross Connection Cabinet and other optical fiber distribution equipment. The splitters are secured within the trays and the trays are tamper-proof to prevent unwanted entry.
FOC COMMUNICATION CO., LTD provides a series of 1xN and 2xN (N=2,4,8,16,32,64) Fiber PLC Splitter Trays which feature low insertion loss, good channel-to-channel uniformity, wide operating wavelength range, excellent environmental stability, and now they’re widely used in PON networks to realize optical signal power splitting as a low-cost solution.
Features
Tamper-Proof Packaging
Low insertion loss
Low Polarization Dependent Loss
Compact design
Excellent Mechanical
Good channel-to-channel uniformity
High Reliability and Stability
Wide Operating Wavelength: 1260~1650nm
Stability Telecordia GR-1221 and GR-1209
Applications
Telecommunications
Local area network
Fiber to the home
Video transmission
Fiber optic sensing
Testing instruments
CATV
Optical Specifications
Parameter | Unit | Specification (P Grade) | |||||
Channel Number |
| 1X2 | 1X4 | 1X8 | 1X16 | 1X32 | 1X64 |
Operation Wavelength | nm | 1260~1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.4 | 10.7 | 13.9 | 17.2 | 21.5 |
Uniformity (Max.) | dB | 0.5 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | ≥50 | |||||
Directivity | dB | ≥50 | |||||
Operating Temperature | ℃ | -40~+85 | |||||
Storage Temperature | ℃ | -40~+85 |
Parameter | Unit | Specification (P Grade) | |||||
Channel Number |
| 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 |
Operation Wavelength | nm | 1260~1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.6 | 11.0 | 14.8 | 17.9 | 21.5 |
Uniformity (Max.) | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | ≥50 | |||||
Directivity | dB | ≥50 | |||||
Operating Temperature | ℃ | -40~+85 | |||||
Storage Temperature | ℃ | -40~+85 |
Note: All the data above does not include connectors.
Ordering Information
PLC |
|
|
|
|
|
|
| Port | Fiber Type | Input | Output | Pigtail Length | Connector |
| 0102=1x2 | 1=G652D, 2=G657A | L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | 05-20=0.5--2.0m, 0=Adapter, X=Others | FU=FC/UPC, FA=FC/APC, SU=SC/UPC, SA=SC/APC, ST=ST/UPC, LU=LC/UPC, LA=LC/APC, 00=None, X=Others |
We can produce many serials of PLC splitters including:
1X2, 1X4, 1X8, 1X16, 1X32, 1X64, 2X4, 2X8, 2X16, 2X32, 2X64 with following package
Bare fiber series
Mini loose tube package
ABS Module type
LGX box type
Rack Mount patch panel for PON application.
Wall Mount patch panel for PON application
Inline fiber optic splice closure type
Erect fiber optic splice closure type