Optical Fiber PLC Splitter Cassette Box SC / UPC , 1×32 Low Insertion Loss And Good Uniformity
PLC splitters are characterized as uniform broadband power splitters / combiners featuring exceptional uniformity of insertion loss throughout all channels resulting in fact in practical wavelength independency over all transmission range from 1260 to 1650 nm.
PLC splitters are the best choice for large variety of telecom and sensor applications. Based on PLC (Planar Lightwave Circuit) technology, PLC splitters optimally balance performance, size and cost.
Cassette type: installed in 19 inch standard rack; in fiber branch home, installation device is provided in the optical fiber cable transfer box; branch home, installed customer specified equipment.
Features
1x4, 1x8, 1x16, 1x32 and 1x64 configurations available
2x4, 2x8, 2x16, 2x32 configurations available
Telcordia GR-1209 & GR-1221 qualified
Low insertion loss, PDL, Back Reflection
High uniformity
Compact package
Applications
PON- FTTX Networks
CATV
Outside Plant Equipments
DWDM and CWDM systems
Optical Specifications
Parameter | Unit | Specification (P Grade) | |||||
Channel Number | 1X2 | 1X4 | 1X8 | 1X16 | 1X32 | 1X64 | |
Operation Wavelength | nm | 1260~1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.4 | 10.7 | 13.9 | 17.2 | 21.5 |
Uniformity (Max.) | dB | 0.5 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | ≥50 | |||||
Directivity | dB | ≥50 | |||||
Operating Temperature | ℃ | -40~+85 | |||||
Storage Temperature | ℃ | -40~+85 |
Parameter | Unit | Specification (P Grade) | |||||
Channel Number | 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 | |
Operation Wavelength | nm | 1260~1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.6 | 11.0 | 14.8 | 17.9 | 21.5 |
Uniformity (Max.) | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | ≥50 | |||||
Directivity | dB | ≥50 | |||||
Operating Temperature | ℃ | -40~+85 | |||||
Storage Temperature | ℃ | -40~+85 |
Note: All the data above does not include connectors.
Ordering Information
PLC |
|
|
|
|
|
|
|
Port |
Fiber Type |
Input |
Output |
Pigtail Length |
Connector |
|
0102=1x2 |
1=G652D, 2=G657A |
L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter |
L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter |
05-20=0.5-2.0m, 0=Adapter, X=Others |
FU=FC/UPC, FA=FC/APC, SU=SC/UPC, SA=SC/APC, ST=ST/UPC, LU=LC/UPC, LA=LC/APC, 00=None, X=Others |