1. CAFS-60/6000 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-60/6000 |
Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 600 L/min; 2. The maximum mixed liquid flow rate is 850L/min; 3. The spraying distance of the fire nozzle is 24 meters; 4. The spraying distance of fire monitors is 40 meters. |
Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa. |
Air Compressor | 1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
2. CAFS-900 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-900 |
Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 550 L/min; 2. The maximum mixed liquid flow rate is 900L/min; 3. The spraying distance of the fire nozzle is 24 meters; 4. The spraying distance of fire monitors is 40 meters. |
Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 1200L/min; Rated pressure: 1Mpa. |
Air Compressor | 1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
3. CAFS-1200 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-1200 |
Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 1050 L/min; 2. The maximum mixed liquid flow rate is 1200L/min; 3. The spraying distance of the fire nozzle is 25 meters; 4. The spraying distance of fire monitors is 40 meters. |
Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa. |
Air Compressor | 1. The maximum flow is 8400L/min@0.7Mpa, the maximum power is 55KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has three pumps combined into a pump group, and the total flow is 60L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
4. CAFS-MK3500 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-MK3500 |
Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 3000 L/min; 2. The maximum mixed liquid flow rate is 3500L/min; 3. The spraying distance of the fire nozzle is 25 meters; 4. The spraying distance of fire monitors is 45 meters. |
Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa. |
Air Compressor | 1. The maximum flow is 22,000L/min@0.7Mpa, the maximum power is 160KW; 2. The maximum working pressure is 1.3Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has nine pumps combined into a pump group, and the total flow is 180L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
5. Company Reference Pictures