Fireproof Entry Doors Fire Rated Steel Entry Doors Grade A Insulated Fire Door
Technical Parameters
Door Closer | 1 |
Door Frame | 1.2mm Cold Rolled Galvanized Steel Sheet |
Door Frame Type | Binding |
Sideboard Width | 120mm 140mm(with earing) |
Door Leaf | 1 70mm |
Door Mirror | 1 |
Fire Lock | 1 |
Fire Hinge | 3 |
Fire Intumescent Seals | 15*2 +12*2 (W*T mm) |
Perlite Fire Door Core Board | 1 (450±45)kg/m³ |
Door Leaf Panel | 2 0.8mm Cold Rolled Galvanized Steel Sheet |
Pattern of Panel | 6 Square Block |
Class | A |
Grade | A |
Fire Resistance Rating | 1.5 Hour |
Name | Fire-Proof Anti-Thief Door |
Dimension | 1000*2100 (mm) |
Standards | GB12955-2008 |
Technical Specification
1. It’s designed based on GB12955-2008 Standards.
2. There is 3mm stiffening plate on the connection of Door Closer, Fire Hinge, Door Leaf and Door Frame.
3. There is C type skeleton with 1.8mm cold rolled galvanized steel sheet inside of the door leaf:
Skeleton 1 67mm*20mm Skeleton 2 67mm*15mm
4. There is Lock box on Fire Lock inside of the Door Leaf: 5mm Fire proof board(110mm*300mm).
Besides, the door frame is also equipped with inlayed Fire expansion strips and installed with Fire seals.By closing there is no impact sound to hear.And thirdly the crossbeam and mullion are welded in 45 degree. The door fan made of high quality cold rolled galvanized steel plate is bent accurately through bending machine, inside of which it is filled with green environment friendly perlite plates which are key to its Fire funktion,and charackters of heat insulation and sound insulation. As to the surface treatment man introduces the process technology without welding spots, thus flat appearance.