Production Description
High-grade wooden decorative fire door can meet the needs of various personalized and customized products with special requirements.
Scope of application: High-end residence, High-grade apartments, 5A Office Buildings and other specific places.
Year Output | 30,0000Pcs | Name | Stoving varnish fire door |
Color | Multiple choice | Special Properties | Fire proof |
Texture | PVC | Size | Customizable |
Frame: after improved process based on M2 door case, increase after grinding, polishing processing, such as mirror surface, the new technology of coated PVC, USES the PUR glue, hot, does not glue, surface texture clear, strong sense of wood grain simulation, waterproof, acid and alkali from natural fire, put out, do not fade, etc.
Fire resistance:
Class a 1.5 hours.
Class b 1.0 hour.
Class c 0.5 hour.
Zhongwo wooden baking paint fire door has elegant appearance and strong fire performance. The surface decoration layer is processed with baking paint and solid wood paste which is coated with natural and precious solid wood skin. It gains the advantages of bright color with strong visual impact, good surface finish, easy to scrub, moisture-proof and sound insulation after many times treatment of spraying and polishing.
Standard hole size
Single open - 0618 0620 0820 0821 0824 0920 0921 0924 1020 1021 1023
Double open - 1220 1221 1223 1520 1521 1523 1820 1821 1823 2020 2021
Determination of the Opening Direction of Fire Doors
The fire door is generally a normally closed external door, and it opens in the direction of evacuation. Standing on the front of the door facing the hinge, if the hinge is on your right, it’s opening outward right.
Fire Resistance Rating Classification
Name | Fire Resistance Performance | Code | |
Fully Heat Insulated Doorsets(Class A)
| Fire Insulation ≥0.50h Fire Integrity ≥0.50h | A0.50 (Grade C) | |
Fire Insulation ≥1.00h Fire Integrity ≥1.00h | A1.00 (Grade B) | ||
Fire Insulation ≥1.50h Fire Integrity ≥1.50h | A1.50 (Grade A) | ||
Fire Insulation ≥2.00h Fire Integrity ≥2.00h | A2.00 | ||
Fire Insulation ≥3.00h Fire Integrity ≥3.00h | A3.00 | ||
Partially Heat Insulated Doorsets(Class B)
|
Fire Insulation ≥0.50h | Fire Integrity ≥1.00h | B1.00 |
Fire Integrity ≥1.50h | B1.50 | ||
Fire Integrity ≥2.00h | B2.00 | ||
Fire Integrity ≥3.00h | B3.00 | ||
No Heat Insulated Doorsets(Class C)
| Fire Integrity ≥1.00h | C1.00 | |
Fire Integrity ≥1.50h | C1.50 | ||
Fire Integrity ≥2.00h | C2.00 | ||
Fire Integrity ≥3.00h | C3.00 |