Specifications
Brand Name :
DAXIAN
Model Number :
DX8930
Certification :
ISO9705:1993
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Packaging Details :
Standard export wooden case
Delivery Time :
30 days after order confirmed
Payment Terms :
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability :
30 sets per month
Standards :
ISO9705:1993
Supply power :
380V, 220V 50Hz
Inverter power :
15KW
Smoke exhaust flow :
≥ 12000m3 / s
Description

Construction Surface Material Fire Test Equipment for ISO9705:1993

Compliance with the standards:

ISO9705:1993.

Scope of application:

It is mainly applicable to the surface material of the inner surface of the wall and the top plate; the main test is the time interval from the start of the test to the occurrence of flashover, the heat released by the combustion per unit time, and the heat released from the combustion of the standard ignition source per unit time.

Technical Parameters:

1. The power supply voltage: 380V, 220V 50Hz

2. The total power of equipment: 16KW

3. Inverter power: 15KW

4. The measurement of volume flow within the exhaust pipe range: 0-2000pa.

5. Smoke exhaust flow: ≥ 12000m3 / s.

6. The gas flow rate: differential pressure transmitter range: 0-25pa, resolution 0-0.5pa.

7. Combustion gas source: propane, purity ≥ 95% (user-supplied).

8. Timing range: 0-240min, timing accuracy <± 1s.

9. Measuring range of heat flow meter: 0-50kw/m2, accuracy ±3%, response time ≤1s, repeatability: ±0.5%.

10. Thermocouple: room temperature ~1000 °C (K value), time constant ≤ 0.1s

11. Gas temperature: 7 armored nickel chromium nickel silicon K thermocouple

12. Surface temperature: 6 armored nickel chromium nickel silicon K value thermocouple

13. Smoke density measurement, transmission rate 0-100%, accuracy <± 3%;

14. Measurement error: ± 1% of range, response time 3s.

15. Electronic mass flow meter, measuring range: 0-70 LSM (0-2.3 g/s) (propane).

16. O2 oxygen analyzer -

17. Measuring range: 0-25 % (range can be set)

18. The maximum measurement error: ± 1% of full scale

19. Response time: < 3s

20. CO, CO2 two-component analyzer.

- Carbon Monoxide Analyzer (CO) Measurement Range: 0-1 %

- Maximum measurement error: ±1% of full scale

- Response time: < 3s

Carbon dioxide analyzer (CO2) —

- Measuring range: 0-6 %

- Maximum measurement error: ±1% of full scale

- Response time: < 3s

21. Preprocessor: imported pumps, valves, compressors, (domestic integration)

22. physical room size: 3.6 * 2.4 * 2.4 (m), the user site construction according to the supplier's construction drawings.

room door size: height 2.00m width 0.80m

room interior net size is 3.00×2.40×2.40(m)

Suitable for use in buildings and large complexes (including locomotives, vehicles, warehouses, and construction methods) as well as extensive verification of fire performance of raw materials, buildings, and solid models ISO9705 ISO5660-1.

Hood cover: square hood, 10M high from the ground, 7.62x7.62M connecting gas discharge and exhaust gas treatment

Exhaust pipe: vertical pipe with internal diameter of 1.524M, through 90-degree elbow, built-in diversion method, can reduce the gas into the pipe in the role of the inside

Smoke concentration: flow rate, temperature and gas composition and concentration

Measuring system: Including pitot tube, thermoelectric pot and gas sampling tube, with 75mm diameter holes on the wall of A section, published at equal intervals

Exhaust fan: The maximum exhaust air volume is 30m3/s

Smoke Density: Photovoltaic and He-Ne Laser Systems for Smoke Density Measurement

Oxygen: Range 025% Accuracy: ±0.05%

Carbon monoxide range: 01% Measurement accuracy: ±0.1%

Carbon dioxide range: 010% Measurement accuracy: ±0.02%

Data processing system: Calculate and record the heat release rate, smoke density and gas concentration obtained from various detectors. The measurement system used to operate the data processing system and the MFC or to open or close various electromagnetic solenoid valves is based on control Independent programming of the program, data acquisition system using high-precision board and host computer Lsd View operating software

Electric Fire Test Equipment ISO9705 1993 For Construction Surface MaterialElectric Fire Test Equipment ISO9705 1993 For Construction Surface Material

Send your message to this supplier
Send Now

Electric Fire Test Equipment ISO9705 1993 For Construction Surface Material

Ask Latest Price
Brand Name :
DAXIAN
Model Number :
DX8930
Certification :
ISO9705:1993
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Contact Supplier
Electric Fire Test Equipment ISO9705 1993 For Construction Surface Material
Electric Fire Test Equipment ISO9705 1993 For Construction Surface Material

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Verified Supplier
7 Years
guangdong, dongguan
Since 2004
Business Type :
Manufacturer
Total Annual :
8,000,000-10,000,000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement