Mask Synthetic Blood Penetration Tester
Standard :
EN14683-2019、ISO22609、ASTMF2100-19、ASTMF1862/F1862M-17
Nozzle diameter :
0.84mm
Spraying speed :
450cm / s, 550cm / s, 635cm / s
Dilivery Time :
3 work days
Warranty :
1 Year
Description

ASTMF2100-19 Mask Synthetic Blood Penetration Tester

Application:
The main purpose of the mask synthetic blood penetration testerA certain amount of synthetic blood is sprayed horizontally on one side of the mask under test with a certain pressure and distance, and the penetration of the synthetic blood on the other side of the mask is observed.


Equipment standard:

GB 19083-2010 ,YY/T 0691-2008,YY 0469-2011,EN14683-2019,ISO22609,ASTMF2100-19,ASTMF1862/F1862M-17.

Characteristics:

1. Convenient mask holding device

2, the pressure of the injection device is adjustable

3. Simple operation of synthetic blood sampling device

Technical index:

Spraying distance adjustable from 300mm to 305mm
Nozzle diameter 0.84mm
Injection pressure point 10.7kPa (80 mmHg), 16 kPa (120 mmHg), 21.3 kPa (160 mmHg)
Spraying speed 450cm / s, 550cm / s, 635cm / s
Including air pressure source 1 set of air compressor


Resistance of Medical Face Masks to Penetration by Synthetic Blood Nozzle Diameter 0.84mm Spraying Speed 450cm / S

Send your message to this supplier
Send Now

Resistance of Medical Face Masks to Penetration by Synthetic Blood Nozzle Diameter 0.84mm Spraying Speed 450cm / S

Ask Latest Price
Brand Name :
Daxian
Model Number :
DX2023
Certification :
GB 19083-2010 ,YY/T 0691-2008,EN14683-2019、ISO22609、ASTMF2100-19、ASTMF1862/F1862M-17
Place of Origin :
China
MOQ :
one set
Price :
Negotiation
Contact Supplier
Resistance of Medical Face Masks to Penetration by Synthetic Blood Nozzle Diameter 0.84mm Spraying Speed 450cm / S
Resistance of Medical Face Masks to Penetration by Synthetic Blood Nozzle Diameter 0.84mm Spraying Speed 450cm / S
Resistance of Medical Face Masks to Penetration by Synthetic Blood Nozzle Diameter 0.84mm Spraying Speed 450cm / S

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Verified Supplier
7 Years
guangdong, dongguan
Since 2004
Business Type :
Manufacturer
Total Annual :
8,000,000-10,000,000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement