IEC 60243-1 Dielectric Strength Of Solid Electrical Insulating Materials Test Equipment
Application:
Apply to continuous uniform boosting or step by step boosting way, step by step toward a sample breakdown, ac/dc voltage until the breakdown voltage measurement, calculation of the sample breakdown strength.
Specifications:
Breakdown voltage | 0~50kV |
Booting speed | 100,200,500,1000,2000,5000(KV/S) |
Booting speed control | Electrical automatic control |
Voltage measurement accuracy | ≤ 2% |
The leakage current selection | 1~100 mA |
Methods of test | DC & AC |
Methods of booting | Automatic program-controlled |
Power Frequency | sine wave 50Hz/60HZ |
Supply power | AC220V 50/60Hz |
Dimension | L 1400* W 1040* H 1500 mm |
Weight | 200kg |
Transformer capacity | 10 KVA |
AC 0~50 KV (continuously adjustable) |
Instructions:
Take out the discharge rod and straighten the telescopic rod, insert the other end of the ground clamp into the metal probe socket of the discharge rod, and then clamp the ground clamp to the ground terminal A or B of the instrument. Bend down, open the glass door of the test chamber, and use the metal probe to touch the output voltage equalizing ball of the high voltage transformer, the electrode on the sample and the high voltage end of the capacitor one by one. (If necessary, use a multimeter to test the voltage between the electrode and the human body in the AC voltage file (AC20V file) after the discharge is completed, which is less than 36v, indicating that the residual voltage has been discharged.)