Specifications
Brand Name :
DAXIAN
Model Number :
DX8401
Certification :
ISO 9239-1 : 2002, ASTM E648-19ae1
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Payment Terms :
L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Supply Ability :
30 sets per month
Delivery Time :
30 days after order confirmed
Packaging Details :
Standard export wooden case
Standards :
ISO 9239-1 : 2002, ASTM E648-19ae1
Measurement range :
( 0-15 ) Kw/m22
Accuracy :
± 0.2Kw/m2
Smoke speed :
( 2.5 ± 0.2 ) m/s
Size :
1400 *500 *710mm
Exhaust stackwith interior dimensions :
102w * 380d * 318h
Description
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test Machine

Scope of application:

- Suitable for testing with a small flame igniting a floor covering material that is placed horizontally and exposed to an inclined thermal radiation field.

- Suitable for all kinds of flooring materials. Such as: textile carpets, cork, wood plastic flooring and floor spraying materials. The device may reflect the burning properties of the flooring material including the substrate used, backing material, underlay material, or flooring material

- Measure and describe the properties of floorings in response to heat and flame under controlled laboratory conditions.

Standard:

ISO 9239-1:2002 :Reaction to fire tests for floorings- Part1: determination of the burning behaviour using a radiant heat source;

ASTM E648-19ae1: critical radiant flux of floor-covering systems using a radiant heat energy source.

Technical parameters:

Heat flux meter measurement range (0-15)Kw/m22
Smoke speed (2.5 ± 0.2) m/s
Smoke extraction capacity (39-85) m/min
Combustion gas flow (0.026±0.002)L/S
Flame height 60-120mm adjustable
Combustion gas propane. (prepared by customer)

1. This machine structure consists of a combustion box and a control box.

2. Heat flux meter accuracy: ±0.2Kw/m2;

3. Heat flux meter accuracy: <±3%;

4. Thermal radiation high temperature measurement range: 400-600 °C, accuracy is ± 0.5 °C;

5. Black body temperature error: ±5°CC;

6. Porous refractory radiant panel size: 300mm × 450mm, able to withstand about 900 °C high temperature;

7. Thermocouples: κ-type stainless steel armored thermocouples with a diameter of 3.2 mm;

8. Heat flux distribution requirements: at 200mm (9.1 ± 0.4) KW/m2; at 400mm: (5.0 ± 0.4) KW/m2;

9. At 600mm: (2.4 ± 0.2) KW/m;

10. Burning torch: 35mm 0.7mm hole in outer diameter g10mm inner diameter c6mm torch tube;

11. Ignition system: high voltage electronic ignition;

12. Burning box size: L1420*W1200*H2300(mm)

Item LIst
1 Test Chamber
2 Radiant Heat Energy
Source
3 Pyrometer
4 Specimen
Holder
5 Pilot Burner
6 Thermocouples
7 Exhaust System
8 Dummy Specimen
9 Heat Flux
Transducer
10 Timing Device

ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test

ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test

Send your message to this supplier
Send Now

ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test

Ask Latest Price
Brand Name :
DAXIAN
Model Number :
DX8401
Certification :
ISO 9239-1 : 2002, ASTM E648-19ae1
Place of Origin :
China
MOQ :
1 set
Price :
Negotiable
Contact Supplier
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test
ASTM E648-19 Fire Testing Equipment Floor Covering Critical Radiant Flux Test

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Verified Supplier
7 Years
guangdong, dongguan
Since 2004
Business Type :
Manufacturer
Total Annual :
8,000,000-10,000,000
Employee Number :
150~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement