ASTM E 1537 Heat Release Rate Tester/Large Calorimeter
Areas of use:
The test method is used for fire technical modelling. The data from the test results can be used for modelling bigger fires. A fire sequence in the ISO 9705 – Room Corner Test and EN 13823 – SBI can for example be predicted using the ISO 5660 method. The cone calorimeter test is also largely used when testing products that are under development. A whole range of different data can be compared in order to eliminate products that will not have the sufficient fire characteristics.
Standards:
- ISO 9705
- ISO 13784-1
- ASTM E 1537
- EN 14390
- ISO5660-1
Structures:
- The equipment consists of an ignition source, conical collector, exhaust pipes, fans, weighing station and measuring device component.
- Test system comprising: a gas collection and analysis system; gas control system; weighing measuring system; smoke density test system;
- Pipeline built-in temperature sensors, gas flow meters, gas sampling probe and a multi-stage filter sampling line analytical instruments to ensure long life.
Performance parameters:
Fire material density | 800kg/m cubed |
Test room size | 3.6m (L)* 2.4m (W)* 2.4m (H) |
Protective cover | 3M(D)*3M(W)*1.05M(H) |
Catheter | 0.4m (diameter), 5M(length including guide plate) |
Sampling probe | 2mm for 17 holes and 3mm for 16 holes |
Door size | 0.9m (W) x2.0m (H) |
Square igniter size | 250*250mm |
Power supply | AC 380V, 50/60hz |
Specification of cabinet | height = 1800mm, width = 900mm, and depth > 600mm |
- The system automatically fires and records relevant experimental data;
- Independent movable timing display platform.
- 10kV spark igniter, equipped with a safe cease-fire device.Fire fighting and drainage system design.
- Bipolar gas flow valve control system;Avoid leakage of air in the system caused by malfunction of solenoid valve, which leads to explosion risk;
- Stair design, convenient exhaust pipe maintenance.
Gas sampling system:
1. High-precision patent design sampling system;Ensure the sampling gas entering the gas analyzer is stable and free from impurities;Make the analysis result of analyzer more accurate;
2. Including particle filter;
3. Cold well: compressor principle refrigeration system;Gas sampling 0 ~ 5 ºC temperature control;
4. Air suction pump: provide gas sampling power source;
5. Drying cylinder;Oxygen and nitrogen dioxide were respectively analyzed for air drying and impurities removal.
6. High precision ball valve;Open and close the air circuit;
7. Flow controller.
Gas analyzer:
1. Simultaneously analyze oxygen consumption, carbon monoxide and carbon dioxide production rate.
2. The resolution of the gas analyzer is: oxygen 0~25%, carbon monoxide 0~1%, and carbon dioxide 0~10%, respectively.
3. Set by-pass for quick response.
4. Data collection system: one set of dedicated collection system and brand lenovo computer