800L Temperature And Humidity Testing Chamber With Safety Protection Device
Applications
The test chamber function is to provide high and low temperature and humidity constant, high and low temperature and humidity alternating test environment; with refrigeration systems, heating systems, humidification / dehumidification / water systems, duct systems, control systems, system safety protection
Main technical
Studio size | 800 × 1000 × 1000mm (depth × width × height) |
Dimensions | 1300 × 1470 × 2100mm (depth × width × height) |
Temperature | 20 ° C |
The temperature fluctuation | ≤ ± 1 ℃ |
The temperature uniformity | ≤ 1 ℃ |
The temperature deviation | ≤ ± 2 ℃ |
The rise and fall rate | From room temperature ~ 20 ℃, about 15min |
Humidity | 65% R.H |
Humidity error | +2 / -3% R.H |
Wind speed | 1.7 ~ 2.5m / s The above indicators are in the ambient temperature ≤ 25 ℃, atmospheric pressure, no load, no load conditions, from the box wall 1/6 space measured test |
Power | about 8.5Kw |
Power | 380V ± 10% V; 50Hz |
Meet the relevant standards and test methods | GB / T2423.22-87Nb GJB1032-90 MIL-STD-2164 / (E / C) GB / T2423.4-93 GB / T2423.34-86 GJB150.9-86 |
Safety protection device
1.Studio over-temperature protection;
2.Heater short circuit protection;
3.Humidifier short circuit protection;
4.Fan overload protection;
5.Compressor overpressure protection;
6.Compressor overload protection;
7.Water cut / water protection;
8.Leakage protection;
9.Safe and reliable grounding device
Temperature And Humidity Testing Chamber.pdf