Submerged Manifold Mount Solenoid Pulse Valve CA76MM
Goyen type manifold mount pulse valve paly an important role in dust collecter system.Pulse valves are used to clean bag-type or cartridge-type filters in a dust collector system. In the production process, the generation of dust is inevitable. As particles enter the machine, it will cause damage to the equipment. Dusty air is also a hazard to workers’ health. Pulse valves are used to clean bag-type or cartridge-type filters in a dust collector system. These valves send a high-energy pulse of air through the blow tube creating a shock wave down the filters to remove dust. Higher air acceleration and quicker valve response time helps clean filter bags better and consume less compressed air, thereby lowering the cost of system operation.
Specification:
Model No. | CA76MM |
Port Size | G3 Inch |
Nominal Size | 76mm |
Number of Diaphragm | 2 |
Valve Type | Full Immersion Manifold Flat Mount Valve |
Working Media | Air |
Working Pressure | 0.3~0.8Mpa |
Working Temperature | -5~+55℃ |
Voltage | AC220V, AC110V, AC24V, DC24V |
Special Voltages and special specifications , please contant us. |
Overall Dimension:

Details ABout CA76MM Electromagentic Pulse Valve:
Goyen Type Aluminium CA76MM
Grey color Goyen type Solenoid Electromagnetic Pulse Valve designed for industrial equipment,professional component for Dust Collector.
Part No. | Nominal Port Size (mm) | Nominal Port Size (Inch) | Number of Diaphragms | Flow (Kv/Cv) | Net Weight(kg) | Outlet Pipe Size |
CA25MM | 25 | 1" | 1 | 26.24/30.62 | 0.8 | 1" |
CA40MM | 40 | 1 1/2" | 2 | 39.41/45.99 | 1.2 | 1 1/2" |
CA50MM | 50 | 2" | 2 | 62.09/72.46 | 2.5 | 50'' |
CA62MM | 62 | 2 1/2" | 2 | 106.58/124.38 | 3.0 | 62'' |
CA76MM | 76 | 3" | 2 | 165.84/193.54 | 3.7 | 76'' |
CA89MM | 76 | 3" | 2 | | 3.5 | 76'' |
CA102MM | 102 | 4" | 2 | 268.29/313.09 | 5.65 | 102'' |



Submerged electromagnetic pulse valve is submerged pulse valve air bags of an electromagnetic pulse valve, submerged electromagnetic pulse valve seat inserts installed in the gas bag, small resistance, good liquidity, high injection quantity, increase the amount of load to drive, enlarged the scope of the use of air pressure, the submerged pulse valve air pressure is more suitable for wider applications.
The compressed air "switch" of the pulsed bag dust remover system with submerged electromagnetic pulse valve is controlled by the output signal of the pulsed jet control instrument. The dust remover is sprayed on the filter bag row by row (chamber) to keep the pressure of the bag dust remover within the set range to ensure the processing capacity and dust removal efficiency of the dust remover.
Connection:
A: threaded connection
B: the intubation tube submerged pulse valve is the diaphragm that divides the pulse valve into the front and rear Chambers. When the compressed air is connected, the compressed air enters the rear chamber through the air hole. At this time, the pressure in the rear air chamber will press the diaphragm against the air outlet of the valve, and the pulse valve is in the closed state.
Installation:
1. Check whether the components are damaged during transportation before use.
2. Before installation, clean up the sundries in the air supply pipeline through ventilation. Pay attention to the direction of gas flow and whether the connection pipe is correct during installation.
3. All o-rings shall be lubricated with suitable lubricant during installation.
4. There are three pins in the solenoid pulse valve coil, and it is equipped with a special plug. One of the pins with the "" symbol is the ground pin, and the user can decide whether to ground or not according to needs. (in general, it is not grounded when the voltage is less than 36V, and it should be grounded when the voltage is greater than 36V.) The other two are coil power pins, which are respectively connected with the terminals corresponding to the sequence of the pulse injection controller and the terminals with the common line of the valve. Note whether the voltage meets the requirements.
The capacity of the air separator shall meet the requirements of providing a stable air source for the electromagnetic pulse valve. The inner wall of the air separator shall be clean and free from rust and other sundries. The air separator shall be free from leakage and shall meet all safety requirements.
6. The valve is connected to the gas bag and blowing tube seal suitable temperature for - 10 ℃ ~ 70 ℃. For high temperature seals, please specify when ordering.